Cooper Wheelock SAFEPATH4 SP4-LOC Installation And Operation Manual Download Page 15

15

Warranty

 Limited Warranty

Cooper Wheelock, Inc. products must be used within their published specifications and
must be PROPERLY specified, applied, installed, operated, maintained, and
operationally tested in accordance with these instructions at the time of installation and at
least twice a year or more often in accordance with local, state and federal codes,
regulations and laws.  Specification, application, installation, operation, maintenance, and
testing must be performed by qualified personnel for proper operation in accordance with
all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories

(UL), Underwriters’ Laboratories of Canada (ULC), National Electrical Code (NEC),

Occupational Safety and Health Administration (OSHA), local, state, county, province,
district, federal and other applicable building and fire standards, guidelines, regulations,
laws and codes including, but not limited to, all appendices and amendments and the
requirements of the local authority having jurisdiction (AHJ). Cooper Wheelock, Inc.
products when properly specified, applied, installed, operated, maintained, and
operationally tested as provided above are warranted against mechanical and electrical
defects for a period of three years from date of manufacture (as determined by date code).
Correction of defects by Cooper Wheelock, Inc providing repairs or a replacement shall
be at Cooper Wheelock, Inc.'s sole discretion and shall constitute fulfillment of all
warranty obligations.
The foregoing limited warranty shall immediately terminate in the event any part not
furnished by Cooper Wheelock, Inc. is installed in the product. The foregoing limited
warranty specifically excludes any software required for the operation of or included in a
product. COOPER WHEELOCK, INC. MAKES NO REPRESENTATION OR
WARRANTY OF ANY OTHER KIND, EXPRESS, IMPLIED OR STATUTORY
WHETHER AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE OR ANY OTHER MATTER.
Users are solely responsible for determining whether a product is suitable for the user's
purposes, or whether it will achieve the user's intended results. There is no warranty
against damage resulting from misapplication, improper specification, abuse, accident, or
other operating conditions beyond Cooper Wheelock, Inc.'s control.
Some Cooper Wheelock, Inc. products contain software. With respect to those products,
Cooper Wheelock, Inc. does not warranty that the operation of the software will be
uninterrupted or error-free or that the software will meet any other standard of
performance, or that the functions or performance of the software will meet the user's
requirements. Cooper Wheelock, Inc. shall not be liable for any delays, breakdowns,
interruptions, loss, destruction, alteration, or other problems in the use of a product
arising out of or caused by the software.
The liability of Cooper Wheelock, Inc. arising out of the supplying of a product, or its
use, whether based on warranty, negligence, or otherwise, shall not in any case exceed
the cost of correcting defects as stated in the limited warranty and upon expiration of the
warranty period all such liability shall terminate. Cooper Wheelock, Inc. is not liable for
labor costs incurred in removal, reinstallation, or for damage of any type whatsoever,
including but not limited to, loss of profit or incidental or consequential damages. The

Summary of Contents for SAFEPATH4 SP4-LOC

Page 1: ...P4 LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number P84767 Rev A Copyright 2006 Cooper Wheelock Inc All rights reserved...

Page 2: ...2...

Page 3: ...RM is fully supervised from the SP40 2 or SP40S panel and contains front panel LED s for remote indications of System Normal System Trouble and Alarm conditions Voice frequency response shall be 275 H...

Page 4: ...so be used to alert against unsafe practices Safety De energize all electrical circuits and equipment associated with installing the SP4 LOC If the HVAC Pushbutton option is being added the circuit ca...

Page 5: ...Lock Pull slam latch with 1 8 security tamper indicator installation holes PC Boards SPRM Environmental Operating Temperature 0 to 49 C 32 to 120 F Storage Temperature 20 to 70 C 4 to 158 F Humidity N...

Page 6: ...nsions for the SP4 LOC Front Mounting COMPLY WITH ALL OF THE LATEST APPLICABLE CODES REGULATIONS LAWS STANDARDS AND GUIDELINES 1 Remove the FRONT DOOR ASSEMBLY from the backbox by removing the eight 8...

Page 7: ...AL HVAC EMERGENCY CUTOFF PUSHBUTTON 8 32 TRUSS HEAD SCREWS FOR MOUNTING THE INNER DOOR Figure 2 Inner Door Assembly 2 Mount the backbox assembly See Figure 3 for mounting holes Insure that the orienta...

Page 8: ...run the appropriate pushbutton and SPRM wiring into the backbox If the optional HVAC pushbutton is installed run the HVAC wiring through a separate conduit away from the push button and remote microp...

Page 9: ...ckbox 7 If applicable mount and wire the optional HVAC Emergency Shutoff pushbutton 8 Connect the pushbutton wiring to the terminal block as shown in Figure 4 SP40 2 and Figure 5 SP40S MASS NOTIFICATI...

Page 10: ...SP40S NOTE The SP40S inputs can be supervised by placing a 10K Ohm resistor across each pair of input terminals on the SP4 LOC terminal block and by switching ON the DIP switches on switch block SW7...

Page 11: ...RM AUDIO STATUS CC 6 5 4 3 2 1 Figure 7 Wiring Diagram SPRM to SP40S This wiring is power limited 10 Mount the INNER DOOR to the backbox using the four 8 32 truss head screws and plastic washers 11 M...

Page 12: ...gure 8 Front Door Layout Operating Instructions SP40 2 Panel _ _ _ TB6 AUX IN AUX CC NAC AUX IN NAC CC W5 W4 SW4 100V 70V 25V 1V AUDIO OUT AUXILIARY INPUT SELECTION JUMPER J4 SELECT 1V POSITION CC NAC...

Page 13: ...IN CC POSITION AUXILIARY INPUT SELECTION JUMPER J4 SELECT 1V POSITION AUXILIARY INPUT SUPERVISION JUMPER JP4 REMOVE FOR SUPERVISION Figure 10 Switch and Jumper locations on the SP40S for SPRM Operati...

Page 14: ...1 2 AND 3 4 KNOCKOUTS PROVIDED ON TOP BOTTOM AND BACK FACE SP4 LOC BACKBOX ORIENTATION LABEL 8 32 TRUSS HEAD 4 INNER PANEL MOUNTING SCREW TERMINAL STRIP AND WIRING HARNESS 1 4 DIAMETER HOLE 6 TO ACCEP...

Page 15: ...furnished by Cooper Wheelock Inc is installed in the product The foregoing limited warranty specifically excludes any software required for the operation of or included in a product COOPER WHEELOCK IN...

Page 16: ...ted to the price applicable to the product or part thereof which gives rise to the claim Cooper Wheelock Inc s liability on any claim of any kind shall cease immediately upon the installation in the p...

Reviews: