![Cooper Tools Cleco 88 Series Operation & Service Manual Download Page 21](http://html1.mh-extra.com/html/cooper-tools/cleco-88-series/cleco-88-series_operation-and-service-manual_2664757021.webp)
21
8, 88 & 35MA AIR SIGNAL OPERATION
PORT "B"
SIGNAL
PORT "A"
SIGNAL
PORT "C"
SIGNAL
METERING
VALVE
OPERATION
MA model tools must be used with a self-relieving valve to allow the clutch to reset. The Metering
Valve can be used to regulate the amount of air entering the tool. Port "C" is upstream from the shut
off valve and can be used for jog starts or injecting oil into the tool. When the self-relieving valve
is opened, the tool starts, and there is line air pressure emitted from Ports "A" and "B". When the
clutch shuts off, Port "A" (Which is down stream from the shut off valve)stops emitting line air
pressure, indicating the tool has shut off. When the self-relieving valve is turned off, it will exhaust
all air and the clutch will reset for another cycle.
PORT "A"
SIGNAL
LINE
ATMOSPHERE
ATMOSPHERE
AIR PRESSURE
TOOL
MODE
VALVE ON
CLUTCH SHUTS OFF
VALVE OFF
PORT "B"
SIGNAL
LINE
LINE
ATMOSPHERE
PORT "C"
SIGNAL
LINE
LINE
ATMOSPHERE
Summary of Contents for Cleco 88 Series
Page 22: ...22 NOTES...
Page 23: ...23 NOTES...