Cooper Surgical Medasonics TRIA P338 Manual Download Page 9

Limited Warranty

This warranty is in lieu of all other warranties, expressed or implied. In the
U.S.A., MedaSonics, Inc. (MedaSonics) warrants this Tria

System against

defects in material or workmanship as follows:

Parts 

– MedaSonics will repair or replace parts in exchange for defective parts

for a period of five (5) years after date of original purchase with no charge for
the parts. MedaSonics reserves the right to determine whether a part should be
repaired or replaced.

Labor

– MedaSonics will repair this instrument with no labor charge for a peri-

od of one (1) year after the date of original shipment when it is shipped to the
MedaSonics Service Center. Transportation and insurance to the Service Center
are to be prepaid by the purchaser.

Limitations

– 

This product is to be used only for the intended and labeled

indications presented in the literature accompanying the product.

This 

warranty shall not apply to any products repaired or altered by anyone not
authorized in writing by MedaSonics. MedaSonics makes no warranty of the
results to be obtained.  MedaSonics’ sole responsibility shall be to replace or
repair this product under the terms stated above and does not cover loss or
damage from external causes such as, but not limited to, weather, theft or
abuse. 

This warranty does not apply to batteries, shipping case or other

accessories, or to damage from shipping, tampering, misuse or negligence.

Preventative maintenance, the refinishing or replacement of any cosmetic
defect or deterioration, or the replacement of batteries unless damaged by a
component failure, is not covered by this warranty.  MedaSonics will not be
responsible for any loss, damage or injury resulting from delay in rendering 
service under this warranty. MEDASONICS SHALL NOT BE RESPONSIBLE FOR
ANY SECONDARY CHARGES OR CONSEQUENTIAL DAMAGES FROM ANY
BREACH OF ANY WARRANTY, EXPRESSED OR IMPLIED. Since some states do
not allow the exclusion or limitation of consequential damages, some of this
limitation may not apply to you.  This warranty gives you specific legal rights,
and you may also have other rights which vary from state to state.

- 16 -

- 15-

Tria Specifications

Size

Speaker Unit

Length 5.25” (133 mm)
Width 2.6” (66 mm) 
Height1.75” (45 mm)

Probe

Height4.7” (119 mm)
Width 1.1” (28 mm)

Weight 

Speaker Unit

9.7 oz. (275 gm) with battery

Probe

1.2 oz. (34 gm)

Doppler Technology

Continuous Wave

Display

Reflective liquid crystal display

Case Material

ABS/Polycarbonate 

Battery Type

One 9V alkaline or rechargeable 
alkaline battery

Battery Life

Typically 250 x 1 minute exams 

Ultrasound 

Frequency

2.36 MHz fetal 

Transmitter

5.1 MHz vascular

Display Rate Performance

Range:  60 - 200 bpm
Resolution:  1 bpm
Accuracy:  3 bpm

Summary of Contents for Medasonics TRIA P338

Page 1: ...General Doppler Cautions and Considerations 12 General Doppler Care and Service 13 Battery Replacement 13 Return Policy 13 Warranty 15 Specifications 16 Ultrasonic Output 17 Definition of Terms 18 Tr...

Page 2: ...Display and 2 MHz Fetal 5 MHz Vascular Probes T345 TRIA Fetal Doppler 2 MHz T346 TRIA Vascular Doppler 5 MHz T336 TRIA Doppler Waterproof Fetal Probe 2 MHz P338 TRIA 2 MHz Fetal Probe P339 TRIA 5 MHz...

Page 3: ...al heart rate display and one or more Doppler probe s that contain the ultrasound transducer and Doppler electronics Choice of a probe depends on the clinical application The MedaSonics Tria 2 MHz Fet...

Page 4: ...e level on the Doppler This increases the audio signal upon which the algorithm can operate and will allow it to lock on to the signal and accurately display the heart rate Standard Fetal Probe The 1...

Page 5: ...ed for proper coupling during underwater use 3 Ensure that the speaker unit and Doppler probe are securely connected through the cord Holding the Doppler probe place the tip on the site to be examined...

Page 6: ...he end of the connector with the notch on the end of the wand and push gently until they snap together 10 9 Note The probe on the dedicated vascular Tria System is permanently wired to the speaker uni...

Page 7: ...e before and after such procedures 7 Useful in emergency medicine and noisy environments to take blood pres sure pulse rates and to evaluate suspected arterial injuries 8 Urological applications inclu...

Page 8: ...s product and can only be performed by your service agent For service contact MedaSonics Service Department at 800 227 8076 or 203 929 6321 Prepaid insured shipment for factory service should be sent...

Page 9: ...d to weather theft or abuse This warranty does not apply to batteries shipping case or other accessories or to damage from shipping tampering misuse or negligence Preventative maintenance the refinish...

Page 10: ...e location of the axial spatial peak in cm 18 17 Definition of Terms Ultrasonic Output Tables Note The uncertainty in these measurements was calculated per NEMA UD 2 Appendix A to be 24 ISPTA0 3 The d...

Page 11: ...e and speaker unit Volume control set Turn up volume too low On LED does not light Battery dead Replace battery when switched on If the problem persists after trying the above suggestions please conta...

Page 12: ...1...

Page 13: ...MEDASONICS User s Manual 15 Forest Parkway Shelton CT 06484 800 227 8076 203 929 6321 fax 203 926 9435 www coopersurgical com Part 054 0223 010 Rev C 10 01 Handheld Doppler...

Reviews: