Obstetrical Use: Fetal System
Product Description 

The MedaSonics Tria Fetal Doppler System consists of a handheld speaker
or speaker with heart rate display unit and 2 MHz Probe.  The probe is con-
nected to the unit via a coiled cord.

Speaker Unit with Optional Accu-Rate Heart Rate Display

The speaker unit is comprised of the electronics, battery compartment,
on/off power control, volume control, on/off and battery life LED indicators,
and optional heart rate display.  The 3.5 mm audio output jack on the top of
the unit allows private listening with an optional stethoscope (available
through MedaSonics) or the connection of a recording device.   

The green LED on the face of the unit is lit when the unit is turned on.  When
the battery falls below optimum performance levels, the yellow LED
becomes lit prompting the user to change the battery.

The Accu-Rate Heart Rate Display  calculates and displays the heart rate
once a signal is obtained.  The rate is displayed in beats per minute and is
averaged over several beats.  By watching the heart-shaped icon on the LCD
display, the user can verify the accuracy of the heart rate display number.  If
the inner, solid black heart icon flashes in sync with the heart tones emitting
from the speaker, then the Doppler has “locked on” to the heart rate signal
and will accurately display the rate.  If the inner heart icon flashes random-
ly in comparison to the audible heart tones, the unit has not “locked on” to
the signal and is erroneously identifying noise as the heart rate.  When this
happens, increase the volume level on the Doppler.  This increases the audio
signal upon which the algorithm can operate and will allow it to “lock on” to
the signal and accurately display the heart rate.

Standard Fetal Probe

The 1-inch diameter ultrasound transducer, located at the tip of the probe,
generates signals which are processed and can be heard through the speak-
er or optional stethoscope.  The transducer frequency is 2.3 MHz.

Waterproof Fetal Probe

The waterproof fetal probe is also a 1-inch diameter ultrasound transducer
transmitting at 2.3 MHz.  It is designed specifically for the assessment of
fetal heart rate and circulation in and during water births.  The probe is
waterproof to IEC Ipx7 specifications.  Caution:  The speaker unit is not
waterproof.  Care must be taken to avoid contact with water.

Probe Retention

The Doppler probe is held fast to the speaker unit with magnets which can
be seen in the pocket on the right side of the unit.  Simply place the probe
gently in the pocket and the magnets will retain the probe for storage and
transport.  While the retention force of the magnets is high, it cannot prevent
the dislodging of the probe under extreme conditions, such as high impact.

Probe Connection

To remove a probe from the system, gently pull the gray connector out from
the base of the probe.  To connect a probe, line up the tab on the end of the
connector with the notch on the end of the wand and push gently until they
snap together.

Note:

The probes on the waterproof and dedicated fetal Tria Systems are

permanently wired to the speaker unit and cannot be removed.

Battery

The Doppler requires one 9V alkaline battery which is located in a compart-
ment in the back of the speaker unit.  Battery life will vary according to fre-
quency and duration of exam.

Summary of Contents for Medasonics TRIA P338

Page 1: ...General Doppler Cautions and Considerations 12 General Doppler Care and Service 13 Battery Replacement 13 Return Policy 13 Warranty 15 Specifications 16 Ultrasonic Output 17 Definition of Terms 18 Tr...

Page 2: ...Display and 2 MHz Fetal 5 MHz Vascular Probes T345 TRIA Fetal Doppler 2 MHz T346 TRIA Vascular Doppler 5 MHz T336 TRIA Doppler Waterproof Fetal Probe 2 MHz P338 TRIA 2 MHz Fetal Probe P339 TRIA 5 MHz...

Page 3: ...al heart rate display and one or more Doppler probe s that contain the ultrasound transducer and Doppler electronics Choice of a probe depends on the clinical application The MedaSonics Tria 2 MHz Fet...

Page 4: ...e level on the Doppler This increases the audio signal upon which the algorithm can operate and will allow it to lock on to the signal and accurately display the heart rate Standard Fetal Probe The 1...

Page 5: ...ed for proper coupling during underwater use 3 Ensure that the speaker unit and Doppler probe are securely connected through the cord Holding the Doppler probe place the tip on the site to be examined...

Page 6: ...he end of the connector with the notch on the end of the wand and push gently until they snap together 10 9 Note The probe on the dedicated vascular Tria System is permanently wired to the speaker uni...

Page 7: ...e before and after such procedures 7 Useful in emergency medicine and noisy environments to take blood pres sure pulse rates and to evaluate suspected arterial injuries 8 Urological applications inclu...

Page 8: ...s product and can only be performed by your service agent For service contact MedaSonics Service Department at 800 227 8076 or 203 929 6321 Prepaid insured shipment for factory service should be sent...

Page 9: ...d to weather theft or abuse This warranty does not apply to batteries shipping case or other accessories or to damage from shipping tampering misuse or negligence Preventative maintenance the refinish...

Page 10: ...e location of the axial spatial peak in cm 18 17 Definition of Terms Ultrasonic Output Tables Note The uncertainty in these measurements was calculated per NEMA UD 2 Appendix A to be 24 ISPTA0 3 The d...

Page 11: ...e and speaker unit Volume control set Turn up volume too low On LED does not light Battery dead Replace battery when switched on If the problem persists after trying the above suggestions please conta...

Page 12: ...1...

Page 13: ...MEDASONICS User s Manual 15 Forest Parkway Shelton CT 06484 800 227 8076 203 929 6321 fax 203 926 9435 www coopersurgical com Part 054 0223 010 Rev C 10 01 Handheld Doppler...

Reviews: