17
EN
1. Make sure transmitter is not in programming mode (no jumper on LK4).
2. Fit one jumper to the LK1 pins, and fit another to the LK3 pins.
3. Momentarily fit a jumper to the LK4 pins and then remove it.
The LED will now flash for all types of transmission except supervision, unless the battery
is low.
To disable the LED:
1. Make sure transmitter is not in programming mode (no jumper on LK4).
2. Fit one jumper to the LK1 pins only.
3. Momentarily fit a jumper to the LK4 pins and then remove it.
The Activity LED will not flash for any transmission. Note that the LED will also not flash to
indicate low battery.
Enabling/Disabling the LED (-01 version)
To enable the Activity LED fit LK3.
To disable the Activity LED remove LK3.
Testing.
1. Put the control unit into engineer walk test.
2. Trigger the transmitter.
3. Make sure the panel receives the alarm.
4. Chose another site for the transmitter if the panel does not receive the signal.
6. Press X on the control panel when you have finished testing, to stop the walk test.