For receivers that use infra-red learn hold the transmitter’s activity LED no more than
50mm away from the infra-red learn sensor on the receiver.
Physical Installation
Mount the back
1. Remove the PCB from the case back.
2. Hold the back in the chosen location.
3. Mark two holes through the fixing slots in the back.
4. Secure the back to the surface using two Type ‘C’ 15mm Domehead screws.
5. Make sure the back is flush against the surface and pushes the tamper bar in far
enough to activate the tamper switch.
6. Re-fit the PCB into the back of the case.
7. If you are using the internal reed switch then mount the external magnet at a suitable
point on the door or window being protected.
NOTE: If you plan to use the
internal reed switch
OR zone 1 then YOU MUST REMOVE
THE JUMPER FROM LK2. (If you wish to retain the jumper link then fit it onto one pin
only.)
Connecting External Door Contacts or N.C. Switches
You can wire external Normally Closed devices (for example the 20mm Quikfit) to the 734r
transmitter. You may connect several contacts in series, but the alarm control unit will treat
them all as one zone. Do not use more than 10m total cable length from the 734r to the
last external contact