Cooper safety VoCall CFVCCM9 Compact Master Installation, Commissioning And Maintenance Manual Download Page 20

19 

 

Outstation Settings 

Scroll to the 

Outstn settings

 menu and press TICK.  This menu consists of a list of all 20 possible lines (M1 through M9 on the 

CFVCCM9 master unit, and S1 through S10 on the CFVCCS10 slave unit, plus a back option.  The outstation location is shown 
with the outstation line number, along with a symbol: 

Select outstation 

 S10-outstation 10 

>  Back 

 M9-Outstation 1 

 

 

Unlocked: this outstation exists. 

          Line through circle: this outstation does not exist or is in fault. 

 

Select the outstation to be configured and press TICK.   
 
This shows a sub menu for each outstation 

M9-outstation 1 

 Back 

>Settings 

 Name 

 

Settings 

M9-outstation 1 

O’stn not detected 

Kind>None 

              :Next 

 

The second line of the display indicates the status of the extension (present or not detected).   
Kind allows you to set the outstation type:  

None (no outstation),  
Phone (Type A handset),  
Refuge (Type B handsfree handset),  
Pullcord (disabled toilet alarm).   

If an outstation is defined as a Pullcord, the master will emit a continuous tone if the toilet alarm is activated.  This tone will cease 
when the master handset goes off hook.  No call can be established with the toilet alarm. 

 

Set Name  

M9-outstation 1 

Name 

>Extension 1      < 

              :Next 

 

Use the navigation keys to change the first character of the extension name, and press TICK to move to the next character.  
Repeat for all characters. Press TICK on the last character to move the cursor onto 

Next

 
Use navigation keys to select 

Next

Save

, or 

Quit

, and press TICK to select option.   

Note: if the memory is protected (locked padlock symbol shown for the exchange), then you will only be able to view this 
information.   
 
The cursor will be on the 

Quit

 option.  Only 

Next 

and 

Quit

 can be selected.  Pressing 

Quit

 will move back to the select outstation 

menu. 

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for VoCall CFVCCM9 Compact Master

Page 1: ...VoCALL CFVCCM9 Compact Master VoCALL CFVCCS10 Compact Master Installation Commissioning and Maintenance Manual www acornfiresecurity com www acornfiresecurity com...

Page 2: ...ment B for all non domestic dwellings Building Regulations Approved Document B also requires all buildings where the public or disabled staff gain access to any floor other than the ground floor using...

Page 3: ...ial all units are on the same mains phase as they are classified TEN 230V powering from different phases can mean a 440V potential can be present in a unit during a major fault incident Anti static ha...

Page 4: ...2 5mm AF ALN key Using the ALN key supplied open the right hand front cover Verify the following items are present 1 9 off outstation line connectors 2 1 off 2 way fault connector 3 1 off 2 way in use...

Page 5: ...k with the following contents a Spare mains fuse b 2 5mm AF ALN key Using the ALN key supplied open the front cover Verify the following items are present 1 10 off outstation line connectors 2 1 off 4...

Page 6: ...will be brought into the panel and remove the required knockouts for cable entry If a knockout is removed fill the hole with a good quality cable gland On the bottom face a single knockout is for the...

Page 7: ...hould be installed to meet the appropriate parts of BS5839 9 2011 and BS 7671 Wiring Regulations Other national standards of installation should be adhered to where applicable Do not test wiring with...

Page 8: ...fety Information Sealed Lead acid batteries contain sulphuric acid which can cause burns if exposed to the skin The low internal resistance of these batteries means large currents will flow if they ar...

Page 9: ...s must be used Disabled toilet call points The revised BS5839pt9 2011 now recognises the addition of disabled toilet call systems to the VoCALL Compact unit however gives no guidance on their use as t...

Page 10: ...9 Handsets Type A Hands Free Refuge Point Type B Disabled Toilet Alarm Master to Slave Connection www acornfiresecurity com www acornfiresecurity com...

Page 11: ...s 2ND Fix Replace the front panel door plate by attaching the ribbon cable lead and fixing with the door hinges Attach all plugs ensuring they fit squarely into the connectors Do not connect battery u...

Page 12: ...levels of accessibility User Manager and Engineer User level is accessible to all Manager level is accessible to those who log in as Manager or Engineer Engineer level is accessible to those who log i...

Page 13: ...n to the CFVCCM9 press the TICK button to show the log in screen Compact M9 Back Login View current fault The log in screen will prompt the user to enter a PIN The default Engineer PIN is 0000 Use the...

Page 14: ...sing outstation 4 10 56 02 01 01 11 Scroll through the root menu using the navigation keys until View fault log is selected Press TICK to enter the View fault log menu Use the navigation keys to scrol...

Page 15: ...inute Second The cursor will be on the first option Day Use the navigation keys to select the correct day then press TICK to move to the Month option Repeat until the current date and time are set and...

Page 16: ...ired then press TICK Both Save and Quit will go back to the root menu Change Engineer PIN The default Engineer PIN to access the configuration menus is 0000 but this can be changed Scroll through the...

Page 17: ...Next Moves cursor back to show log option Exec Executes command to clear log if clear log option is set to yes and moves back to root menu Quit Moves back to root menu Panel Settings Depending upon l...

Page 18: ...desired then press TICK Both Save and Quit will go back to the root menu Relay Settings The In use relay has multiple settings None In use Connected or Ignored None the relay is ignored In Use the rel...

Page 19: ...batteries have just been added or changed Battery test Mains OK Batt OK Action Quit Press up or down to toggle between Quit and Retest Press TICK to select that action Define Outstation This menu opti...

Page 20: ...station type None no outstation Phone Type A handset Refuge Type B handsfree handset Pullcord disabled toilet alarm If an outstation is defined as a Pullcord the master will emit a continuous tone if...

Page 21: ...y identify the master unit Use the navigation keys to select the node ID for this master unit and press TICK to move to the next option We must now tell the system how many M9 s should be present on t...

Page 22: ...sing the TICK key The tone will remain silent for 4 minutes whereupon it will recommence This tone signifies that the toilet alarm has been activated and it can occur simultaneously with the Master Ha...

Page 23: ...until all points are tested Record results in the site log Monthly Test one outstation by lifting the handset followed by the master calling that outstation Record results in the site log Quarterly En...

Page 24: ...23 Technical Specification www acornfiresecurity com www acornfiresecurity com...

Page 25: ...PR211 183 505 01 PINSTCFVCCM9 www acornfiresecurity com www acornfiresecurity com...

Reviews: