Features
• Available in 1, 2 or 3 light fixtures
• Splayed trim inserts have a 1/2” flange
• Architectural deep regress rectangular trim with 77º
tapered aperture provides excellent cut-off
• Independently adjustable locking lamp holders with
368º x 45º adjustability
• Adjustable Plaster Frame can accommodate 1/2” to
1-3/8” ceiling thickness
• Configured with integral electronic transformers
• Electrical J-Box and transformers easily accessed from
below the ceiling
• Includes butterfly brackets for black iron installations
• Optional Relay Emergency Module allows the conversion
of one of the fixture’s lamps to function as a remote emergency
unit when supplied by a 12V DC emergency power source.
Module does not contain batteries. Will operate with 85W
lamp maximum. Wattage consumed in emergency mode is
lamp w 0.9W. (
See page 33 for details.)
Combo EdgE - ACCEnt/downlight
Fixture Type
CED1M16
(1) One Light 12V MR16
CED2M16
(2) Two Light 12V MR16
CED3M16
(3) Three Light 12V MR16
Wattage
20
20 Watt 12V MR16
37
37 Watt 12V MR16
42
42 Watt 12V MR16
50
50 Watt 12V MR16
71
71 Watt 12V MR16
Trim Finish
BK
Black Alzak
WH
White Powder Coat
C
A
Clear Alzak
PT
Custom Color (Specify)
Voltage
120
120V (Standard)
277
277V
Emergency Lighting
EM
Relay Emergency Module
Ordering Example
CED3M16-37-CA-120
3 Light Combo Edge Accent/Downlight for MR16 lamp, 37 watt,
Clear Alzak trim, 120V
Options
Optical accessories include: Baffles, Snoots, Louvers and
Lenses. See page 33 for details.
COMBO EDGE - ACCENT/DOWNLIGHT - 12V MR16
#
!
"
%
$
& '
v
HOUSING DIMENSIONS
FIXTURE TYPE
A
B
C
CEILING CUT-OUT
1 Light
11.66”
6.66”
11.84”
5.27” x 5.30”
2 Light
15.51”
6.66”
11.84”
9.30” x 5.30”
3 Light
19.36”
6.66”
11.84”
13.15” x 5.30”
COMBO EDGE - A
CCENT/DOWNLIGHT - 12V MR16
TRIM DIMENSIONS
FIXTURE TYPE
D
E
F
G
1 Light
4.50”
5.60”
4.50”
5.60”
2 Light
8.52”
9.62”
4.50”
5.60”
3 Light
12.37”
13.47”
4.50”
5.60”
3 light fixture shown above
Also available in 1 light and 2 light fixtures
TRIM INSERT FINISHES
Black Powder Coat
White Powder Coat
Clear Alzak
#ONNECTS
TO*BOX
Optional Relay Emergency
Module - add “-EM” to the end
of the catalog number