The 2, 5, 7, and 10 button Chilli Control Panels from 
Cooper Controls provide an elegant solution.  These  
buttons are used to output a memory or sequence which 
has been previously programmed into the Chilli / Spice 
dimmers on the network or to turn the outputs off. 

Where fitted, raise, and lower buttons compliment the 

usual selection buttons to allow immediate changes to 
the intensity of any memory.
An optional infrared remote control allows similar  
functionality from anywhere within the room via the  
detector built into the front panel of the Chilli Control 
Panel (2, 5, and 7 button only).   The Chilli Control Panel  
is connected to the dimmers using a Chilli Network  
connection.

Chilli Control Panel

Installation guide

Supplied parts

Front cover

Screws

Main body

Dimensions

The Chilli Control Panel fits into standard single gang 

47mm deep UK backbox.  Backboxes available from 
Cooper Controls.

Series 3 Panels (Clip-on Cover)

Use the screws provided to attach the panel to the  
backbox before clipping the front cover onto the  
assembly.

86.01 mm (3.39 in)

86.01 mm (3.39 in)

39.01 mm 
(1.54 in)

Fixing to a wallbox

Introduction

Welcome

Summary of Contents for 2 Chilli Control Panel

Page 1: ...y from anywhere within the room via the detector built into the front panel of the Chilli Control Panel 2 5 and 7 button only The Chilli Control Panel is connected to the dimmers using a Chilli Network connection Chilli Control Panel Installation guide Supplied parts Front cover Screws Main body Dimensions The Chilli Control Panel fits into standard single gang 47mm deep UK backbox Backboxes avail...

Page 2: ...at either end of the chain The Chilli Control Panel is supplied with termination enabled as standard If the Chilli Control Panel is not connected as an end device in the chain you need to disable termination To disable termination move the jumper from the upper two pins to the lower pins as shown here The following cable strategies may be used for wiring the Chilli Network It is not recommended to...

Page 3: ...mber in the message 4 Press the Memory 1 or OFF button to exit setup mode Memory 1 Press the 1 button Memories 1 4 Press the corresponding memory button Memories 1 4 Press the corresponding memory button Memories 1 6 Press the 1 6 button if not already selected then press the corresponding memory button Memories 7 12 Press the 7 12 button if not already selected then press the corresponding memory...

Page 4: ...tput in the corresponding area will be faded out over three seconds Sequences The 10 button Chilli Control Panel can be used to playback output any of the three sequences programmed in the Chilli dimmers on the network for the corresponding area Sequences can be stopped from any Chilli Control Panel on the network that is assigned to the same area in which the sequence is running Starting a Sequen...

Page 5: ...connected to 0 volts all button presses on control panel are ignored and a last man out message is sent out Key 3 When Key 3 connected to 0 volts button presses on control panel are not ignored and a last man out message is sent out Chilli Network Alarm State Chilli dimmers on the network have an Alarm Input When this alarm input is activated or changes from active to inactive the dimmer sends out...

Page 6: ...the goods have been damaged by accident abuse misuse modification or misapplication by damage during shipment or by improper service There are no warranties which extend beyond the hereinabove limited warranty INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS No employee agent dealer or other person is authorized to give any warranties on beha...

Reviews: