 CAUTION

• 

Before changing the filter or cleaning, 

turn off the unit and disconnect its power 

supply.

• 

When removing filter, do not touch metal 

parts in the unit. The sharp metal edges can 

cut you.

• 

Do not use water to clean the inside of the 

indoor unit. This can destroy insulation and 

cause electrical shock.

• 

Do not expose filter to direct sunlight when 

drying. This can shrink the filter.

Air Filter Reminders (Optional)

Air Filter Cleaning Reminder

After 240 hours of use, the display window on 

the indoor unit will flash “CL.” This is a reminder 

to clean your filter. After 15 seconds, the unit will 

revert to its previous display.

To reset the reminder, press the 

LED

 button 

on your remote control 4 times, or press the 

MANUAL CONTROL

 button 3 times. If you don’t 

reset the reminder, the “CL” indicator will flash 

again when you restart the unit.

Air Filter Replacement Reminder

After 2,880 hours of use, the display window on 

the indoor unit will flash “nF.” This is a reminder 

to replace your filter. After 15 seconds, the unit 

will revert to its previous display.

To reset the reminder, press the 

LED

 button 

on your remote control 4 times, or press the 

MANUAL CONTROL 

button 3 times. If you don’t 

reset the reminder, the “nF” indicator will flash 

again when you restart the unit.

 CAUTION

• 

Any maintenance and cleaning of outdoor 
unit should be performed by an authorized 
dealer or licensed service provider.

• 

Any unit repairs should be performed 
by authorized dealer or licensed servic e 

provider.

Maintenance – 

 

Long Periods of Non-Use

If you plan not to use your air conditioner for an 

extended period of time, do the following:

Clean all filters

Turn on FAN function until 

unit dries out completely

Turn off  the unit and               

disconnect the power 

 

Remove batteries  

from remote control

Maintenance – 

 

Pre-Season Inspection

After long periods of non-use, or before periods 

of frequent use, do the following:

Check for damaged wires

Clean all filters

Check for leaks

Replace batteries

Make sure nothing is blocking all air inlets and outlets

Ca

re and 

Maintenance

Summary of Contents for Sophia CH-S30FTXW-SV

Page 1: ...HEATING SYSTEM OWNER S MANUAL Models CH S30FTXW SV 230V CH S36FTXW SV 230V SOPHIA IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to s...

Page 2: ...g and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they ha...

Page 3: ...r damage WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill wat...

Page 4: ...ables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket...

Page 5: ...professional national wiring regulations requirement of National Electrical Codes NEC and local electrical codes by authorized personnel only WARNING wire which can t be used for other purposes The g...

Page 6: ...t be installed in the line Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add the fence for safety purpose For the air conditioner...

Page 7: ...SWING TURBO or SILENCE features are turned off when defrosting when anti cold air feature is turned on when unit is self cleaning when freeze protection is turned on Display Code Meanings Functional F...

Page 8: ...els with low temp cooling systems To further optimize the performance of your unit do the following Keep doors and windows closed Limit energy usage by using TIMER ON and TIMER OFF functions Do not bl...

Page 9: ...s the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth Unit Specifications and Features Wi Fi Control some units Wi Fi control allows you to...

Page 10: ...e set by remote control please refer to the Remote Control Manual NOTE ON LOUVER ANGLES When using COOL or DRY mode do not set louver at too vertical an angle for long periods of time This can cause w...

Page 11: ...C after 1 hour and will increase an additional 2 F 1 C after another hour When in HEAT mode the unit will decrease the temperature by 2 F 1 C after 1 hour and will decrease an additional 2 F 1 C after...

Page 12: ...anel of the indoor unit 2 Locate the MANUAL CONTROL button on the right hand side of the unit 3 Press theMANUAL CONTROL button one time to activate FORCED AUTO mode 4 Press theMANUAL CONTROL again to...

Page 13: ...lth Make sure to clean the filter once every two weeks 1 Lift the front panel of the indoor unit 2 Grip the tab on the end of the filter push it up slightly then pull it a little towards yourself 3 No...

Page 14: ...on the indoor unit will flash nF This is a reminder to replace your filter After 15 seconds the unit will revert to its previous display To reset the reminder press the LED button on your remote cont...

Page 15: ...the unit from overloading The unit cannot be restarted within three minutes of being turned off The unit may change its setting to prevent frost from forming on the unit Once the temperature increase...

Page 16: ...e Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mitigated by cover...

Page 17: ...et of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive...

Page 18: ...the voltage Poor heating performance The outdoor temperature is lower than 44 5 F 7 C Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows a...

Page 19: ...door ambient then theSophia indoor unit will discharge the heat to the room The Sophia heating capacity decreases as the outdoor temperature decreases During extreme cold outdoor temperatures you may...

Page 20: ...s can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs airflow means you could be heating and cooling the back of a chair or the front of a sofa...

Page 21: ...ws All warranty periods begin on the date of original installation If the date cannot be verified the warranty period begins one hundred twenty 120 days from date of manufacture If a part fails due to...

Page 22: ...to start due to voltage conditions blown fuses open circuit breakers or damages due to the inadequacy or interruption of electrical service 6 Failure or damage due to floods winds fires lightning acc...

Reviews: