Cooper & Hunter MALTA CH-2835 Instruction Manual Download Page 8

www.cooperandhunter.com

6

NOTE:

The filter cartridge is attached to the water tank cap. If you

are not going to use the filter, you should remove it by

turning it counterclockwise.

Never run the unit when there is no water in water basin

IMPORTANT! 

5) Linder standby status, if you press the compound button, LED ring will 
light up in green. Mist will escape from the mist outlet;
6) For more information on the compound button and LED ring, please 
refer to “Compound Button and LED Ring” specified in Operation 
Instruction;
7) During operation, if LED ring turns from green to blink in red and no 
mist is coming out, it means “water shortage protection” is activated.
Add water into water tank and put back the water tank in place. After 
that, restart the humidifier;
8) If you want to use the fragrance function, add a few drops of fragrance 
liquid into the fragrance duct on the mist outlet cover.

NOTE:

Never add fragrance directly into the water tank or water 

channel.

7. CLEANING AND MAINTENANCE OF THE UNIT

IMPORTANT! 

Always switch off and unplug the unit before 
cleaning

You  can  ensure  many  years  of  trouble  free  operation  of  your  humidifier
by following a few simple maintenance procedures.
In  some  areas,  water  quality  is  hard  and  water  is  rich  in  calcium  and 
magnesian ions. After using the humidifier for a period, some calcium and 
magnesian  ions  will  be  deposited  on  the  nebulizer  and  become  scale, 
which will affect humidifying performance. In addition, the active carbon filter 
attached at the air inlet will filter out the large grained dust. After using the 
humidifier for a long time, the filter will absorb plenty of dust from air, which 
will also affect the humidifying performance. The cleaning and maintenance 
method for humidifier is introduced as below:
1. Clean the nebulizer, water tank and water channel frequently.
2.  Change  the  used  water  in  water  tank  frequently  to  ensure  clean 
humidification.
3. If humidifier won’t be used for a long time, unplug the power cord and 
clean  the  humidifier.  After  cleaning,  wipe  it  dry  and  then  put  it  into  the 
original package box. Keep it in a cool and dry place. 

How to clean nebulizer:

 1. Add about 10ml (you may adjust the volume according to the extent of 
scale) of vinegar onto the surface of nebulizer and let it stay for 2~5 minutes. 
2. Use a brush to gently clean the surface of nebulizer until the scale is 
removed. 3. Wash the surface of nebulizer with clean water.

How to clean water tank:

1. Add a few drops of vinegar or 5 - 10 drops of detergent into the water 
tank. Then add water until it occupies 1/4 of the volume of water tank.
2. Twist the water tank cover to make it tight. Then shake the water tank 
repeatedly. After that, wash it with clean water. 

Summary of Contents for MALTA CH-2835

Page 1: ......

Page 2: ......

Page 3: ...Instruction manual Model Ultrasonic air humidifier CH 2835 Outlook of devices aslo colour scores can be revised without any special advance notices...

Page 4: ...air humidity results in drying of mucous membranes which in its turn is the reason for decrease in immunity headache lip cracking sandpaper in the eyes it also enables infection spreading and respirat...

Page 5: ...asing Do not operate the unit without water in the basin Do not insert foreign objects into the device Do not touch the transducer or the lower water basin when the unit is operating Do not scratch th...

Page 6: ...ng becomes brighteras mist volume is increased Mist volume remains the same after it is adjusted to the maximum Decrease mist volume Turn the compound button in counterclockwise direction LED ring bec...

Page 7: ...tion Take off the water tank nut see Fig 2 Then add water into the water tank After it is filled with water turn the water tank nut in clockwise direction to tighten it up 3 Put back the water tank Be...

Page 8: ...m and magnesian ions After using the humidifier for a period some calcium and magnesian ions will be deposited on the nebulizer and become scale which will affect humidifying performance In addition t...

Page 9: ...ules of the section Cleaning and servicing the device can lead to the development of micro organisms bacteria inside the pan That will lead to unpleasant smells and violation of hygienic norms Use as...

Page 10: ...1 2 3 4 5 6 7 8 9 10 10 11 11 13 Cooper Hunter Cooper Hunter 40 60 220 240 50 1 8 14 9 15 www cooperandhunter com 8...

Page 11: ...30 C 2 www cooperandhunter com 9...

Page 12: ...3 4 5 20 1 220 240 50 3 5 23 38 IP20 1 0 2 30 40 280 20 www cooperandhunter com 10 269x267x324 LED...

Page 13: ...www cooperandhunter com 11 2 30 30 30 40 1 5 1 1 2 1 3 1 6 1...

Page 14: ...www cooperandhunter com 12 2 2 3 3 4 5 6 7 8 2 3...

Page 15: ...www cooperandhunter com 13 1 2 3 1 5 10 2 5 2 3 4 1 7 2 3 5 10 1 4 5 10 1 2 3 4 80...

Page 16: ...www cooperandhunter com 14 8 12...

Page 17: ...www cooperandhunter com 15 9 12...

Page 18: ..._____________________ _____________________________________________ _____________________________________________ _____________________________________________ ________________________________________...

Page 19: ...Cooper Hunter International Corporation Oregon USA www cooperandhunter com E mail info cooperandhunter com 03127 132 380 44 461 79 82 380 44 461 78 93...

Page 20: ......

Reviews: