background image

10

HEALTH SAVE button

7

HEALTH FUNCTION:

After pressing HEALTH button, remote controller will switch circularly as below:

"HEAL

TH"→"AIR"→"AIR HEA

L

TH"→"no display"

● 

When selecting "HEALTH" by remote controller, HEAL

TH function will be started up.

● When selecting "AIR" by remote controller

AIR function will be started up.

● When selecting "AIT

 HEALTH", 

AIR and HEA

L

TH function will be started up.

● When there

s no display on remote con

troller, 

AIR and HEA

LTH function will be 

   turned off.

● AIR function is applicable for some models. 

Introduction for buttons on remote controller

Note: 

When selecting "    " with remote controller, it’

s auto swing. Horizontal louver of air 

conditioner will swing up&down automati

c

ally at the maximum angle.

When selecting "    

   

    

   

、 

swing. Horizontal louver of air conditioner

 will stop at that position as shown by the

icon to swing.

● When selecting "     " with remote controller, it

s auto swing. Horizontal louver of 

   air conditioner will swing left&right automatically at the maximum angle.

● When selecting "    

    

    

    

   

"

   position swing. Horizontal louver of air conditioner will stop at that position as 

   shown by the icon to swing.

● When selecting 

Note: 

There is no this function for the units. If press this key, the main unit will 

             click,  but it also runs under original status.

"                          ", it’s the circulating swing. Horizontal louver of 

   air conditioner will swing circularly according to the angle as shown by the icon.

(swing angle is displayed dynamically)

6

     button

no display

(horizontal louvers stops 

at current position)

(swing angle is dis-

played dynamically)

● Press this button to start or stop left & right swing function. The remote controller

   defaults to simple swing condition.

● Press + button and      button at the same time at unit OFF to switch between

   simple swing and static swing;      blinks for 2 seconds.

● In static swing condition, pressing     button, the swing angle of left & right louver

   changes as below:

● If the unit is turned off during swing operation,the louver will stop at present 

   position.

Summary of Contents for GWH09KF-A3DNB4A

Page 1: ...GH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM OWNER S MANUAL Models GWH09KF A3DNB4A 115V GWH12KF A3DNB4A 115V GWH09KF D3DNB4F 230V GWH12KF D3DNB4F 230V GWH18KG D3DNB4F 230V GWH24KG D3DNB4A 230V ALI...

Page 2: ...3DNB4A I GWH12KF A3DNA5A O GWH09KF D3DNB4F 230V System Includes GWH09KF D3DNB4F I GWH09KF D3DNA5F O GWH12KF D3DNB4F 230V System Includes GWH12KF D3DNB4F I GWH12KF D3DNA5F O GWH18KG D3DNB4F 230V System...

Page 3: ...ons on display screen 7 Introduction for buttons on remote controller 8 Function introduction for combination buttons 12 Operation guide 13 Replacement of batteries in remote controller 13 Emergency o...

Page 4: ...s situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard re...

Page 5: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 6: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Page 7: ...ables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket...

Page 8: ...al national wiring regulations requirement of National Electrical Codes NEC and local electrical codes by authorized personnel only Precautions WARNING wire which can t be used for other purposes The...

Page 9: ...89 6 73 4 32 23 109 4 78 8 43 26 Maximum heating 80 6 27 75 2 64 4 24 18 The operating temperature range outdoor temperature for cooling only unit is 64 4 F 18 C 109 4 F 43 C for heat pump unit is 19...

Page 10: ...different from above graphics please refer to actual products Indoor Unit air inlet panel horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver windo...

Page 11: ...e X FAN is same with BLOW 9 TEMP button 10 TIMER button 11 TURBO button 12 SLEEP button 13 LIGHT button 7 HEALTH SAVE button 6 button FAN OPER AUTO HEALTH AIR FILTER TURBO ON OFF X FAN HOUR HUMIDITY U...

Page 12: ...t indicator on indoor unit is ON You can press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust swing angle Cooling only unit can t receive the signal fo...

Page 13: ...igh medium or low speed according to ambient temperature Fan speed under dry mode is low speed 5 Press this button to start or stop up down swing function The remote controller defaults to simple swin...

Page 14: ...swing Horizontal louver of air conditioner will swing left right automatically at the maximum angle When selecting position swing Horizontal louver of air conditioner will stop at that position as sho...

Page 15: ...ambient temperature When selecting by remote controller temperature indicator on indoor unit displays outdoor ambient temperature SAVE function Under cool mode press SAVE button and the unit will oper...

Page 16: ...isappear Press this button again to turn on the light for indoor unit s display icon on remote controller will be displayed Child lock function Switchover function for temperature display Press and bu...

Page 17: ...2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall Durin...

Page 18: ...ated object to press the auto button Clean and maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditi...

Page 19: ...to a certain Use dust catcher or water to clean the filter When the filter is very dirty use the water below 113 F 45 C to clean it and then put it in a shady and cool place to dry panel cover tightly...

Page 20: ...nage pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are re...

Page 21: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Page 22: ...emperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper...

Page 23: ...unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or...

Page 24: ...he unit If not please It can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not pl...

Page 25: ...charge the heat to the room The alice heating capacity decreases as the outdoor temperature decreases During extreme cold outdoor temperatures you may need an additional heating source to supplement t...

Page 26: ...can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs airflow means you could be heating and cooling the back of a chair or the front of a sofa i...

Page 27: ...ect in materials or workmanship under normal use and maintenance as follows All warranty periods begin on the date of original installation If the date cannot be verified the warranty period begins on...

Page 28: ...age conditions blown fuses open circuit breakers or damages due to the inadequacy or interruption of electrical service 6 Failure or damage due to floods winds fires lightning accidents corrosive envi...