4.3 Installation
The dimensions of the mounting bracket and the
unit installation are indicated in Fig. 4.3.
4.3.1 Mounting Bracket onto Wall
When the mounting bracket is directly attached
to a wood wall or a concrete wall, check to ensure
of
0.45kip
(
2000N
).
Mounting on a Concrete Wall or a Concrete Block
Wall: Attach the mounting bracket to the wall with
anchor bolts as shown in Fig. 4.4.
Mounting Bracket
Screw
Fig. 4.4 Mounting on Concrete Wall or
Concrete Block Wall
Fixing Screw for
Mounting Bracket
Mounting
Bracket
Utilize Six Screws.
NOTE
The mounting bracket should be installed
so that the side of drain piping connected
is slightly (about
1 8
(
)) lower than
the other side, in order to avoid the
incorrect position of the drain discharge.
(Drain piping connection can be performed
both right side and left side of the unit.)
9 8
(
)
Plug
Drill holes with
depth of
1-17/64in.
(
32mm
) in the wall