3) Select the heating function:
• When the device is on, press the heating function button (3) to
set it going.
When this function is active, the heating PTC heats up the water
in the base to help counteract the bacteria and creates a warm
mist.
• Press the button again to turn the heating function off.
the heating function is independent of all the other functions and
modes. It can therefore be activated and deactivated at any time.
Notice: If heating function is active before entering sleep mode, it
will be still active after entering sleep mode, but heating indicator
light is off, only sleep mode indicator light is on. If heating function
is activated after entering sleep mode, heating indicator will stay
on for 5 seconds, then all the lights are off except the sleep mode
indicator lights on.
Never run the unit when there is no water in water basin
IMPORTANT!
Never touch the heating PTC (10) before it has cooled
down!
In the event of accidental burns, consult a doctor!
IMPORTANT!
4) Adjust the timer:
• When the device is on, press the button repeatedly that sets the
timer (4) to set the device going for 1 to 12 hours. The screen will
display the time selected or “CO” for continuous for 5 seconds.
After 5 seconds, the screen automatically switches to the real
time ambient relative humidity. In this case, press timer (4) again,
the screen will display and flash its remaining hours for 5 seconds,
during the 5 seconds just press it repeatedly to select desired
timing hours. When the timing hours reached, all the functions will
stop, except the fan, which will continue to run for 15 seconds.
CO (default) -01-02-03-04-05-06-07-08-09-10-11-12
5) Adjusting the humidity level:
When the device is on, press the button that sets the humidity
level (5) repeatedly to set the automatic humidity control going at
the level required from 40 to 75% in increments of 5%. The LED
screen will display the level selected or “CO” for “by default” for 5
seconds. We recommend a level of humidity between approxim-
ately 40 and 60%. The device will stop running when the ambient
air reaches the required level and resumes when this rate drops.
CO (default) - 40% - 45% - 50% - 55% - 60% - 65% - 70% - 75 %
6) Adjusting the emission intensity:
• When the device is on, it emits mist at a medium intensity.
• Press the button for selecting the emission intensity (6) once:
the device will emit mist at the highest intensity intensity.
• Press a second time and the device will emit mist at the lowest.
• Press a third time and the device will emit mist at medium
intensity.
- Only use fresh, distilled or demineralised water to avoid
any malfunction.
- Do not pour water into the mist nozzle (1) in order to
avoid any malfunction and risk of fire.
- The tank must be kept clean. Please refer to the
cleaning instructions below.
IMPORTANT!
Diffusing essential oils
To diffuse essential oils, push the aroma drawer (7) so that you can remove
it. Pour 1-3 drops onto the pad inside.
Make sure that the oil does not touch any other part of the device as this
may damage the materials.
Summary of Contents for Cayman Series
Page 1: ......
Page 2: ......
Page 13: ...30 C 2 www cooperandhunter com 11...
Page 15: ...www cooperandhunter com 13 3 7 1 2 3 4 5 6 7 LED 5 1 1 2 1 3 1 4 1 6 30 5 40 80 40...
Page 18: ...www cooperandhunter com 16 7 1 2 3 100 10 3 3...
Page 19: ...www cooperandhunter com 17 6 1 2 9 PTC 10 1 2 5 2 5 2 11 3 PTC 4 2 1 2 3 1 1 2 12...
Page 20: ...www cooperandhunter com 18 8 60...
Page 21: ...www cooperandhunter com 19 12 9 12...
Page 23: ...www cooperandhunter com 21 2 30 C...
Page 25: ...www cooperandhunter com 23 3 7 1 2 3 4 5 6 7 LED 5 1 1 2 1 3 1 4 1 6 30 5 40 80 40...
Page 28: ...www cooperandhunter com 26 1 2 3 100 10 3 3 7...
Page 29: ...www cooperandhunter com 27 6 1 2 9 PTC 10 1 2 5 2 5 2 11 3 PTC 4 2 1 2 3 1 1 2 12...
Page 30: ...www cooperandhunter com 28 8 60 8...
Page 31: ...www cooperandhunter com 29 12 9 12...
Page 33: ......
Page 34: ......