background image

NOTE:

 Top rail and side panels at each side are offset to provide the proper pitch to the rear of

           (5/16  ). This is necessary for proper condensed water utilization and drainage. If you are

           not using the side panels for any reason, this pitch to the rear must be maintained.  

,,

1

A. Hold the side panel in one hand 

    and gently pull back the center to 

    free the open end. See Fig.1.

B. Slide the free end "

" section of the panel

    directly into the cabinet as shown in Fig. 2. 

    Slide the panel down. Be sure to leave enough 

    space to slip the top and bottom of the frame 

    into the rails on the cabinet.

Fig.1

Fig.2

"

"section

        Place unit on floor, a bench or a table. There is a 

proper

panel for each side. When installed, the flange for

securing the panel in place to the window sill will be

facing into the room.

C.  Once the panel has been installed on the side of 

      the cabinet, make sure it sits securely inside the 

      frame channel by making slight adjustments. 

      Slide the top and bottom ends of the frame into the

      top and bottom rails of the cabinet. Fig.3.

D.  Slide the panel all the way in and repeat on the 

      other side. 

NOTE:

 If storm window blocks AC, see Fig. 10.

Top Rail

Bottom Rail

Fig.3

Installation Instructions

10

How To Install

left and right side filler panel; be sure to use the 

Summary of Contents for MWDCK-06CRN1-BK2

Page 1: ...WINDOW AIR CONDITIONER s Model MWDCK 06CRN1 BK2 MWDCK 08CRN1 BK3 MWDCK 10CRN1 BK3 MWDCK 12CRN1 BK3...

Page 2: ...13 14 15 20 1 2 OPERATING INSTRUCTIONS REMOTE CONTROL OPERATING INSTRUCTIONS 3 9 5 4 5 6 7...

Page 3: ...2 grounding place grounding A damaged appliance...

Page 4: ...any other purpose than air cooling 3...

Page 5: ...with a new cord please Please contact Customer Service contact Customer Service Safety Precautions 4 Operation of Current Device...

Page 6: ...Indoor temp 17 32 90 Note Performance may be reduced outside of these operating temperatures 5 Operating Instructions Air Conditioner Operation Normal Sounds SAFETY PRECAUTIONS its similar...

Page 7: ...perate on Auto feature In this mode the fan speed cannot be adjusted it starts automatically at a speed according to the room temperature When you set the air conditioner in AUTO mode it will automati...

Page 8: ...vious temperature setting or room temperature when the unit is on When the unit is off there is no display time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop timed program This...

Page 9: ...d as shown in the left picture HS Electric heating sensor error Unplug the unit and plug it back in If error repeats call for service Error codes AS Room temperature sensor error Unplug the unit and p...

Page 10: ...led screwdriver 6000 8000BTU hr 3 4 or 1 Screws 7 2 Lock Frame 2 Sash Lock 1 Window sash seal foam 1 Packaging Fig E Top Rail E Fig D INTERIOR WALL Wooden Windows WINDOW SILL H H NOTE The top rail har...

Page 11: ...d bottom of the frame into the rails on the cabinet Fig 1 Fig 2 section Place unit on floor a bench or a table There is a proper panel for each side When installed the flange for securing the panel in...

Page 12: ...gh the frame lock and into the sill NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 4 window frame Fig 5 Fig 6 Fig 7 Drive 3 4 19mm or 1 2 12 7mm locking scr...

Page 13: ...or condensation must be allowed to drain out Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 10 Removing AC From Window Turn AC off and disconnec...

Page 14: ...stead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to u...

Page 15: ...Troubleshooting Tips 14 workmanship c c l h h h l d t...

Page 16: ...ns Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries AAA batteries back of the remote protect the environment getting powered containers to 15 Handling the remote con...

Page 17: ...Function buttons RG32A E 2 AAA batteries 16 ft 5 m Model Rated Voltage Signal Receiving Range Environment Lowest Voltage of CPU Emitting Signal NOTE The unit will initiate automatically the Energy Sa...

Page 18: ...een automatically controlled 3 If the Auto mode is not comfortable for you the desired mode can be selected manually NOTE In the Fan mode the setting temperature is not displayed in the remote control...

Page 19: ...Remote Control Operating Instructions 1 F 1 C pressing to in temperature in 1 F 1 C 18...

Page 20: ...Remote Control Operating Instructions 19...

Page 21: ...rvicing 6 Damages to finish after installation EXCLUSIONS This warranty does not cover the following 1 Failure caused by damage to the unit while in your possession other than damage caused by defect...

Reviews: