background image

Temperature setting

 

 

1

Temperature 

settings, press the 

temperature 

setting    icon,then 

switch to the 

temperature 

setting interface. 

 

1.1

Press+ /―key to 

set temperature for 

COMFORT and 

ECONOMIC 

MODE,after set up, 

press conform key, 

exit to home page. 

 

2 Timer set up and modify 

 

1

Press timming 

key. 

 

2

Switch to timed 

mode interface.   

Picture shows

Tuesday, 

ECONOMIC 

MODE. 

 

3

Select timing P 

programe. 

Picture shows : 

Tuesday, P1 

program. 

 

 

4

Set up a multi day 

timer and select the 

same P program. 

Picture 

shows :Monday to 

Sunday, P1 program.   

Summary of Contents for AG80JT-W20

Page 1: ...MANUAL INSTRUCTIONS HEATER PLEASE READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...ice agent or similarly qualified persons in order to avoid a hazard The heater must not be located immediately below an electrical socket outlet Don t use this heater in the immediate surroundings of a bath a shower or a swimming pool Do not use this heater with a programmer timer separate remote control system or any other device that switches the heater on automatically since a fire risk exists ...

Page 3: ...lled in the outside volume only according the national wiring rules For France NF C 15 100 Note The above drawing is for reference only We suggest that you to contact a professional electrician for assistance If you are not sure we suggest that you to contact a professional electrician for assistance Mounting the device To install your device Make sure distances to walls and objects are respected ...

Page 4: ...Caution Before switching on the appliance make sure that the radiator is correctly fixed to the wall ...

Page 5: ......

Page 6: ...haracteristics of the Wireless module a Frequency band in which the radio equipmentoperates 2 4G band WiFi device 2400 2483 5MHz 5 8G band motion sensor device 5725MHz 5875MHz b Maximum radio frequency power transmitted in the frequency band s in which the radio equipment operates 2 4G band WiFi device Max radio frequency power transmitted 17 21dBm 52 6mW 20dBm 100mW 5 8G band motion sensor device...

Page 7: ... switch the mode COMFORT MODE ECONOMIC MODE ANTIFREEZE MODE TIMING MODE SENSOR MODE PROGRAMMING MODE 2 LED Display Icon Description Icon Description Time PROGRAMMING MODE Week 1 to 7 WIFI icon Program P1 to P7 Window open icon Temperature display Child lock except power button COMFORT MODE Heating icon ECONOMIC MODE Left slide screen Icon for switch mode from left side appears ANTIFREEZE MODE Righ...

Page 8: ...re is 7 C so that any frost risk can be avoided When the room is empty for long time such as vacation please use this mode Note that the temperature cannot be set 2 4 PROGRAMMING MODE The radiator is controled by external control box Under PROGRAMMING MODE 6 modes are available 1 Comfort 2 Comfort 1 3 Comfort 2 4 Economic 5 Anti frozen 6 Power off 2 5 TIMING MODE For the first time or for a long t...

Page 9: ...s it automatically jumps to the P program setting 5 The P1 program switches between programs by press and key select program P1 P7 1 M onday then press mode key to 7 Sunday exit If there is no operation in 30 seconds it automatically jumps to the home page 6 After selecting the program on the seventh day Sunday press the mode button to return to the timing master interface 7 Illustration Icon Desc...

Page 10: ...ss and key to modify the P1 program Press to operate COMFORT MODE press button to operate ECONOMIC MODE 6 After modify the program press mode button to exit 7 Then press the mode button to view or modify other programs P1 P7 1 Monday press mode key to 7 Sunday press an d button to modify other programs press mode button to exit If there is no operation in 30 seconds it automatically jumps to the h...

Page 11: ...ogram P1 COMFORT MODE 6 00to22 00 The rest time is ECONOMIC MODE P2 COMFORT MODE 19 00 to 6 00 The rest time is ECONOMIC MODE P3 COMFORT MODE 6 00 to 9 00 and 16 00to 22 00 The rest time is ECONOMIC MODE P4 COMFORT MODE 6 00to 9 00 12 00 to 14 00and 16 00to 22 00 The rest time is ECONOMIC MODE P5 ECONOMIC MODE 0 00 to 24 00 P6 COMFORT MODE 0 00 to 24 00 P7 COMFORT MODE 16 00to 22 00 The rest time ...

Page 12: ...s to decrease temperature adjusting range is 5 5 stepping by 1 After set up press to switch function F1 Induction function Press to add time items press to reduce time item totally 5 time items exist 0 15 30 45 60 min If user want to set 15 minutes press after set up F2 Window open function Press to open Window open functio press to 0 Window open function is closed re open heating time can be set ...

Page 13: ...I icon will turn on after configures the radiator turn back to homepage 6 Set up on APP home page it has Adding radiator Temperature Timer Mode options 7 If APP can t connect radiator a Check the internet works or not bad internet will effect connecting to radiator the distance should be in 10 meter no wall to stop internet Suggest to use in same room b Make sure mobile phone s WIFI function has o...

Page 14: ... current WIFI and password 5 When radiator isin standby state icon flickering on LCD 6 Long press 7 Connect to WIFI time starts counting down from 60 59 58 00 8 Press the confirm key to set up the current WIFI and password ...

Page 15: ...PP connecting 10 APP connect successfuly 11 Radiator connect successfuly 12 Return to standby state LCD show time and is on Operate instruction for APP homepage fuction 1 Press key 2 Enter to APP homepage ...

Page 16: ...ndicate heating Current radiator ambient temperature is 14 0 Temperature set up check temperature for COMFORT ECONOMIC ANTIFREEZE MODE modify the COMFORT ECONOMIC MODE s temperature ECONOMIC MODE set up to 19 ANTIFREEZE MODE set up to 7 WIRE CONTROL MODE TIMING MODE can edit timed program SENSOR MODE ON OFF button Home page button Device list checking button Adding device button EXIT button ...

Page 17: ...ture for COMFORT and ECONOMIC MODE after set up press conform key exit to home page 2 Timer set up and modify 1 Press timming key 2 Switch to timed mode interface Picture shows Tuesday ECONOMIC MODE 3 Select timing P programe Picture shows Tuesday P1 program 4 Set up a multi day timer and select the same P program Picture shows Monday to Sunday P1 program ...

Page 18: ...ter loosening the hand the middle time will disappear COMFORT ECONOMIC ANTIFREEZE MODE icon appear in the same time 5 2 Select Antifreeze mode and press the Save key then exit to home page Picture shows Tuesday P1 program change to Antifreeze Mode 6 Set up and return to the home page 7 After APP modified LCD displays 7 1 Only in timing mode all the operation keys are locked except button Picture s...

Page 19: ...nd device deletion 1 APP homepage 2 Press the device key and switch to the device list a The status of each device can be reviewed b Open and close other devices c Select a device name slide left to set the internal parameter settings separately 2 1 Slide to left setting internal parameters separately 2 2 Press switch to device internal parameter setting list a Temperature compensation Sense funct...

Page 20: ...to reset Reset to Defaults When plugged to the power source press button for 10 seconds to reset your radiator and reinstall the original factory configuration Full screen display for 3 seconds to power off status press to turn on the radiator display COMFORT temperature is 19 ECONOMIC temperature is 15 5 time displays 0000 day of week displays 1 timing is blank P1 P7 is default setting data for t...

Page 21: ...y a neutral detergent cleaner or non abrasive solvent The thermostat housing is made of plastic do not use solvents for maintenance Any repair must be carried out by the manufacturer its representatives or by the after sales service WARNING Never cut the power cable supplied with your radiator if it is cut the electrical part of the radiator can not be guaranteed Never try to open the radiator eve...

Page 22: ...heat output room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control no In standby mode elsb 0 001 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic room temperature control plus day timer no electronic room temp...

Page 23: ...heat output room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control no In standby mode elsb 0 001 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic room temperature control plus day timer no electronic room temp...

Page 24: ...heat output room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control no In standby mode elsb 0 001 kW Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic room temperature control plus day timer no electronic room temp...

Page 25: ......

Page 26: ...te or in the environment is prohibited They are asked to take them to one of the selective collection centers planned by the municipal administration to ensure their recycling You also have the option of depositing your product at your distributor if you buy a product of the same type By respecting this approach you contribute to the preservation of natural resources and the protection of human he...

Reviews: