19
During display of values Thi, Tlo and CND, these may be put back to 0 by
pressing additionally the info button.
Pressing this button for approx. 3 sec. starts a manual defrost.
During each defrosting process display shows “
dEF
” and the LED
defrost lights.
After the defrost process the display shows “
rEc
” for 10 Min.
Should the display show one of the following alarms, a horn
sounds at the same time which may be switched off by pressing
the button for 3 sec.
HI
= temperature 10
°
C beyond set rated value
Ho
= temperature 10
°
C below the set rated value
Do
= door open for more than 2 minutes
HP
= high pressure compressor (devices with built-in beverage cooling
counter machine only)
E1
= probe T1 defective
E2
= probe T2 defective
CL
= clean the condenser
When pressing button, display shows the preset rated value
(+2
°
C = factory setting)
By pressing additionally the button or the value may be changed.
Pressing button for approx. 2 sec. brings the device into the
energy saving mode and the LED „ECO“ lights.