8. MAINTENANCE
Read the instructions contained in this chapter carefully. They contain the basic principles of
maintenance of the blast chiller-freezer.
8.1. SAFETY
When performing works related to cleaning, keep in mind the following safety rules (see also item 3):
•
Do not remove and do not tamper with protective devices while performing regular maintenance
work.
•
Do not work with the equipment with wet hands or feet.
•
Do not put any devices or kitchen tools into the cover of electrical and mechanical parts.
•
Use appropriate and compatible equipment for maintenance.
•
When not in use, the equipment should be switched off and the plug should be taken out of the
power socket.
•
Do not pull the cable of the probe measuring the temperature of the product so as not to remove
it from the product.
•
Do not warm the probe measuring the temperature inside the product with flames.
The products are made with utmost care so as to guarantee the highest safety standards to the
customers.
8.2. CLEANING
Before cleaning starts, disconnect the equipment from the power supply mains:
•
Clean steel surface on the inside and on the outside of the equipment with a damp cloth and a
neutral, non-abrasive cleaning agent. Wipe the surfaces thoroughly with a piece of cloth (do not
rinse them with water) and dry them thoroughly.
•
Do not scrub the surfaces with sharp objects.
•
Do not use any aggressive substances or solvents because their residues may damage the
machine and interfere with its operation.
•
Perform cleaning (of the condenser) with compressed air or a brush with long bristle.
•
Do not use metal, sharpened, or other objects that may cause damage.
8.3. CARE
In order to ensure high quality of the equipment for a long time, implement the following precautions:
•
Handle the probe measuring the temperature inside the product with care because the sensor
is very sensitive.
•
When the equipment is not used for a long time, apply a protective film of Vaseline oil with a
piece of cloth.
•
During down periods, clean and dry the interior. Leave the door slightly open to improve the
circulation of air.
When the equipment is not in use for a long time, disconnect it from the power supply.