7.13. HACCP report
In order to access the HACCP report, press the
HACCP symbol; then select the appropriate day to
verify the HACCP data and confirm by pressing the
search button.
A table is displayed where all cycles conducted in a
given day can be seen. After a cycle has been
selected, an HACCP report is displayed after several
seconds.
The graphic element can show different temperature
values depending on the type of cycle performed:
Time cycle; only the air temperature is displayed.
A cycle with a food probe; the air temperature and
the food product center are displayed.
Then the minimum temperatures and the maximum
temperatures measured during the cycle are shown.
Time cycle; the air probe temperatures are
displayed.
A cycle with a food probe; the temperatures inside
the food product are shown.
7.14. Help (option)
The scope of help is divided into two segments: one
which is password protected and is intended for the
service technician and one which is intended for the
user and is not password protected.
In the segment intended for the service technician
there are video files that show ways to repair the
machine,
e.g. ways to replace the fan or to access the
electrical parts.
The segment intended for the user contains video
files showing ways to use the machine,
e.g. how to switch on a cycle, set a program, or
display an HACCP report.
7.15. Modem (option)
LED GSM
The work mode of the modem is
related to the available SIM card. The
customer has to buy a SIM card. The
SIM card must be charged up so as to
enable sending text messages.
GSM number: enables entering the telephone
number to which the machine sends text messages
with alarms.
Press the button and enter the telephone number,
starting with the country prefix,
e.g. +390000000000
.
The modem has the following functions:
1) In the event of an alarm, the modem sends a text
message to the GSM number with identification of
the type of the alarm,
e.g. alarm, air probe.
2) If the power supply is cut of, the modem
immediately sends a warning text message to the
GSM number,
e.g. alarm, blackout.
3) The machine can verify the status of each GSM
number in real time. In order to obtain such
information, an inquiry must be sent to the number of
a SIM card bought and installed by the user.