COOL
The fan speed is expressed in percentage points between 1% and 100%.
The system has been pre-set to provide a 5 minute WASH cycle before the fan starts. Water is circulated
over the pads to wash off any dust. To by-pass this WASH cycle, press FAN and then COOL.
Every 5 hours a periodic drain cycle empties the tank of water. This 5 hour cycle may be altered if
required. See reference Water Manager Periodic Drain Time.
When the air conditioning system is switched off, the water tank is emptied and a fresh tank of water is
taken in. This fresh water is used to perform an 8 minute FLUSH cycle. Fresh water rinses and cleans
the pads of any impurities or minerals left from the cooling evaporation process. To by-pass this FLUSH
cycle, press FAN then OFF.
As a final process, the tank is emptied of water leaving it clean and dry.
Once the end of day FLUSH cycle has commenced it takes 15 minutes to complete. The FLUSH cycle
can be stopped sooner than 15 minutes by pressing FAN before OFF.
FAN
The FAN mode is useful when the outside ambient temperature has dropped and no direct cooling is
required.
EXHAUST
A delay occurs when switching to EXHAUST mode. This protects the motor and allows it time to stop
before the rotation is reversed.
Exhaust mode is useful for expelling odours from the home without the in-rush of air experienced with the
COOL and FAN modes. It is particularly useful in winter when a cold draft of air is not desirable.
OFF
OFF Mode displays the current ambient temperature.
TIMER
Each subsequent press of the TIMER key, increments the timer by 30 minutes, up to a maximum of 99
hours, 30 minutes.
Pressing the OFF key, or any of the mode keys cancels any unelapsed time from the timer.
If the air conditioning system is turned off, pressing the TIMER key switches it on in COOL mode when the
timer reaches zero.
Conversely, if the system is operating in either COOL, FAN, or EXHAUST modes, the system switches off
when the timer reaches zero.
QA CONTROLLER