GB
Turning on the heating
• Press the green flash 0 / 1
• Wait a few seconds TEST - The display shows internal temperature
• Press the SET button. Press the [
▲
] [
▼
] to raise - lower temperature.
Wait a few seconds and reappear the instantaneous temperature.
The operation of the heating element is displayed in the upper left "out 1".
Switching off the heating
• Press the green flash 0 / 1
Factory parameters
Tripping 5 °
Maximum temperature 85 °
Minimum temperature 50-70 ° C
Setting the controller parameters DIGIT
• Press the green flash 0 / 1
• Wait a few seconds TEST - The display shows internal temperature
• Simultaneously press [
▲
] [
▼
] to 4 seconds. Appears on the display "PA"
• Press "SET".
• Press on [
▲
] [
▼
] until you get the parameter "- 19"
• Press "SET" appears "PA"
• Simultaneously press [
▲
] [
▼
] to 4 seconds. Appears on the display "SP"
Tripping probe
• Press on [
▲
] [
▼
] until you get the parameter "R0" press "SET" and press the [
▲
] [
▼
]
until you get the parameter "2" press "SET".
Maximum temperature
• Press on [
▲
] [
▼
] until you get the parameter "R2" press "SET" and press the [
▲
] [
▼
]
until you get the parameter "80 to 85" press "SET".
Minimum temperature
• Press on [
▲
] [
▼
] until you get the parameter "R1" press "SET" and press the [
▲
] [
▼
]
until you get the parameter "50" "SET" button.
• Simultaneously press [
▲
] [
▼
] to 4 seconds
• Press the green flash 0 / 1 and leave off for 60 seconds
• Press the illuminated green 0 / 1 and press the [
▲
] [
▼
] or press SET to display the
set temperature.
TECHNICAL DATA Temperature DIGIT
Protection class IP 65
Power supply 230 VAC 50/60 Hz 3 VA
Insulation Class 2
Maximum load current 10A.
USE DIGITAL THERMOSTAT
GRX 1