Cooke & Lewis CLLED60-BK Instruction Download Page 5

5

          Cooker Hood           

Getting

Started

...

Getting

 started...

GB IE

Before 

you

 start

 

06

Safety

 

 

10

 

Summary of Contents for CLLED60-BK

Page 1: ...Cooker hood CLLED60 BK CLLED70 BK CLLED90 BK Version 01 GB IE Cooker hood Barcode 5052931536917 5052931536924 5052931536931 WARNING Read the instructions before using the appliance...

Page 2: ...01 x 1 04 x 2 05 x 1 02 x 1 03 x 1 06 x 1 07 x 1 Cooker hood...

Page 3: ...1 1 12 x 4 3 9x18 13 x 6 3 9 x 32mm 08 x 4 10 x 1 09 x 4 11 x 6 14 x 4 3 4 x 10mm Cooker Hood...

Page 4: ...more detail 12 Product functions Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information Guarantee CE Declaration of conformity 13 13 14 17 18 19 21 23 Ap...

Page 5: ...5 Cooker Hood Getting Started Getting started GB IE Before you start 06 Safety 10...

Page 6: ...operation Accessible parts may become hot during use Young children should be kept away Care should be taken to avoid touching the appliance The Manufacturer highly recommends that this appliance be...

Page 7: ...ord is damaged it must be replaced by the manufacturer its order to avoid a dangerorinjury Do not allow the electric cables to touch the hot parts of the appliance Make sure that the power cord is not...

Page 8: ...ke sure the maximum air room does not exceed 4 Pa 0 04 mbar The room must have adequate ventilation if an extractor hood is used simultaneously with appliances that run on gas or other fuels The used...

Page 9: ...distances between the top of cooker or hob and the lowest part of the cooker hood must be observed Gas hobs 750mm Electric hobs 650mm The Manufacturer declines all liability for personal or material...

Page 10: ...e and pass it on to any future owners After unpacking the cooker hood please check that it is not damaged If in doubt do not use the appliance but contact Customer Services on 0 44 800 1128 UK 01 4475...

Page 11: ...6mm CARBFILT4 UK IE OR CARBFILT4CL FR SELF ADHESIVE ALUMINIUM TAPE Recirculation Extraction CARBON FILTER ORDERING HOTLINE 0 44 800 1128 UK 01 4475261 IE 125mm or 150mm 125mm or 150mm Alumnium 11 Get...

Page 12: ...more detail In more detail GB IE Product functions 13 Operation 13 Care and maintenance 14 Troubleshooting 17 Recycling and disposal 18 Technical and legal information 19 Guarantee 21 CE Declaration...

Page 13: ...he appliance is ready for operation functions Five button panel Extractor fan operating control pilot light Lighting on and off Extractor fan off Extractor fan speed button speed 1 Extractor fan speed...

Page 14: ...e carrying out maintenance work on the hood In the event of a fault contact customer services Bulb replacement The Bulb may be hot leave it 10 minutes before replacement Turn to replace the Bulb 10 DO...

Page 15: ...Care and maintenance 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER CARBFILT4 UK IE OR CARBFILT4CL FR CLICK 15 In more detail GB IE Cooker Hood...

Page 16: ...leaning process Important the hood is used for more than 2 hours a day Always use genuine Care and maintenance FUSE OFF Warning Always switch off the electricity supply before performing maintenance w...

Page 17: ...ht and motor do not work Light bulb blown Replace with a bulb with correct rating Power connection loose Check power supply Suction performance reduced Speed may be too low Select a higher speed Dista...

Page 18: ...lection point for recycling On ensuring that this product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health which could occur if this...

Page 19: ...CHED FUSED SPUR OUTLET FUSE ON EUR UK OFF N Blue N Blue L Brown L Brown Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with...

Page 20: ...Connection Before connecting the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the appliance WARNING THIS APPLIANCE MUST NOT BE EARTHED The appliance...

Page 21: ...e has been repaired or replaced any remaining balance of the GAA guarantee will be valid and any further call outs during this prescribed period will be covered by GAA on the replacement appliance Sho...

Page 22: ...at it cannot be removed it is the responsibility of the customer installer to remove and reinstall the appliance to facilitate the repair This Guarantee does not affect your statutory rights The guara...

Page 23: ...he national law Standard EN 60335 1 Safety of household and similar electrical appliances Standard EN 60335 part 2 31 particular requirements for range hoods Standard EN 55014 Limits and methods of me...

Page 24: ...UK IE VENT PACK 2 24 Installation You can choose two type of installation Ducted option Recirculation option device in accordance with these instructions may Warning Failure to install the screws or...

Page 25: ...02 DIM B DIM B MIN 750mm MIN 650mm 170mm 122mm 34mm 170mm 90mm Gas Electric MAX 735mm 25...

Page 26: ...13 x 2 11 x 6 03 04 Maximum gap between top 2 holes and middle 2 holes can be no more than 735mm dependant on ceiling height 13 x 2 03 2mm 2mm 2mm 11 13 03 13 26 735mm...

Page 27: ...tighten with the allen key ensuring not to over tighten as this may cause damae to the glass 10 08 x 4 09 x 4 12 x 4 Insert the 4x bolts rubber washer and washer and tighten with the allen key ensurin...

Page 28: ...07 08 28 Position the hood over the top two screw then fix the bottom screws from inside the hood Replace the aluminium Filter 13 x 2...

Page 29: ...09 10 07 14 06 14 x 2 06 07 29 Fix the Ducting Tube 125 or 150 using tape or clamp Vent Pack 2 UK IE x 1 Fix the Collar and the reducer if required...

Page 30: ...11 12 30 02 14 02 x 1 14 x 2...

Page 31: ...13 31 For recirculating option refer to Care and maintenance section Note For electrical connection see Technical and legal information section...

Page 32: ...r wki Informaci n ErP de la bombilla incluida Informations ErP de l ampoule fournie r nle birlikte verilen ampul n ErP bilgileri 32 95 2 0s 7500 x 10 mg 220 240V 50Hz 220 240 V 195 3 15000 W h Lumen 1...

Page 33: ...1 6 Fluid Dynamic Efficiency FDEhood 9 8 Energy Efficiency Index EEIhood 84 6 Measured air flow rate at best efficiency point QBEP 208 6 m 3 h Measured air pressure at best efficiency point PBEP 123...

Page 34: ......

Page 35: ......

Page 36: ...GB IE B Q plc Chandlers Ford Hants SO53 3LE United Kingdom www diy com...

Reviews: