14
When connected to a mains outlet using the factory fitted plug, the software will limit the hob
maximum power to 2800 W. Once configured as a permanent installation, the maximum power
output is 6400 W.
Replacing the Cable
1. Remove the screw and terminal cover.
2. Remove the factory fitted cable and replace it with the correct grade for the permanent
installation as per the connection diagram above.
WARNING:
DO NOT CONVERT THE HOB TO HIGH POWER WHILST STILL CONNECTED WITH
THE FACTORY FITTED CABLE AND PLUG.
ENSURE THE CABLE CONVERSION HAS BEEN COMPLETED BEFORE PROCEEDING TO
THE SOFTWARE CONFIGURATION.
FAILURE TO DO THIS THIS WILL DAMAGE THE HOB AND INVALIDATE YOUR WARRANTY!
CONVERSION TO PERMANENT WIRING
CAUTION: THE FOLLOWING SECTION IS FOR PROFESSIONAL
QUALIFIED ELECTRICAL INSTALLERS ONLY!
202161_s1_s1_CLIND60ERF_SM_Cooke & Lewis_A5_IM_Multi_V03.indd 14
202161_s1_s1_CLIND60ERF_SM_Cooke & Lewis_A5_IM_Multi_V03.indd 14
12-05-2020 12:17:30
12-05-2020 12:17:30