1.
Under the condition of the whole machine running, click the key and key
3 seconds at the same time.
2.
After 3 seconds,
t
he display of the Cooker Hood show
s
"A" and flashes 5 seconds. After 5
seconds, the di
splay
stops flashing. At this point, the Cooker hood
enters AUTO mode, and the
working gear of the Cooker hood is automatically adjusted
according to the
operating
status of the
induction cooker.
I
n automatic mode, the display only
show
s
"A".
Exit automatic mode combination
In the Cooker Hood of automatic mode,
press
the key
s
and
at the same time for 3 seconds.
The display of the Cooker Hood show
s
"8" and flashes 5 seconds to cancel automatic
mode,
then
the
display will show the current working level of the Cooker Hood.
0
3
Auto mode combination
EN
Use
IMPORTANT: The extraction rate of the hood will vary based upon the total power output selected on the
hob, as shown in the table below.
Each hob cooking zone has a maximum rated output of 10 comprising 1-9 and Boost (10).
NOTE: Full power or Boost only operates for five minutes maximum to conserve energy and the fan speed
will automatically drop to speed level 5 after this time.
Speed 1
This speed will be selected when there are no more than two cooking zones in use,
and the combined output is 8 or less. For example, zone 1 is on 2, and zone 2 is on 5.
Speed 3
This speed will be selected when there are no more than three cooking zones in use,
and the combined output is between 9 and 24. For example, zone 1 is on 7, zone 2 is
on 6 and zone 3 is on Boost (10).
Speed 5
If the
combined output
of different burners are more than
24 when there are no more
than three cooking zones in use, or
all burners on with
the combined output
less than
or equal to
35.
For example, zone 1 is on 8, zone 2 is on 8 and zone 3 is on 9.
Speed P – Boost This speed will be selected when all four cooking zones are in use, and the
combined output is greater than 35. For example, zone 1 is on 9, zone 2 is on 9, zone
3 is on 9 and zone 4 is on Boost (10).
Note:
Speed 2 and Speed 4 on the hood are not available when using this function.
If the hood controls are manually overridden when the hob and hood are linked, the hood will operate for fi ve
minutes on this manual setting before returning to control by the hob.
Summary of Contents for 5059340127514
Page 1: ...5059340127514 CLFLEXDOWN A B Induction Booster Flexi zone Flexi zone Induction Booster...
Page 2: ...Preparation 03 Care and Maintenance 32 EN Contents Installation 19 Use 21...
Page 8: ...05 06 x7 x7 x10 A B C 20mm x2 x1 AF AG DD CC AA AG AG DD AF EN Preparation CC A B C EE JJ...
Page 9: ...07 08 20mm x2 x1 AF AG MGG AA CC DD MGG AA CC BB DD EN Preparation...
Page 11: ...11 12 0 3 X 2 04 X 4 04 X 4 EE EN Preparation 280mm...
Page 12: ...13 W X D x20 15mm x5 x5 EN Preparation W W D CC x2 AR AR 90 AR AR AR 14 AR...
Page 20: ...EN Installation A B RECIRC KIT 1 EN Only for ducted option EN Only for recirculation option 20...