Electrical Installation
All installation must be carried out by a competent person or qualified electrician. Before connecting the mains supply
ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
This appliance must be connected directly to the mains using an omnipolar circuit breaker with a minimum opening
of 3mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it complies with the
wiring diagram.
The cable must not be bent or compressed.
Regularly check the mains connection and power cord for damage. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid a safety hazard.
WARNING: This is a Class I appliance and MUST be earthed.
This appliance is supplied with a 3 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
Green and Yellow = E or Earth
220-240V~
N
L
L
N
N
L
L
Blue
Br
ow
n
(Blue)
(Brown)
(Green/Yellow)
This appliance should be connected directly to the consumer unit with a 32 Amp Residual Current Device
(RCD) protecting its circuit.
To avoid the risks that are always present when you use an electrical appliance it is important that this appliance is
installed correctly and that you read the safety instructions carefully to avoid misuse and hazards. Please keep this
instruction booklet for future reference and pass it on to any future owners. After unpacking the appliance please
check that it is not damaged. If in doubt, do not use the appliance but contact Customer Services shown in the Care
& maintenance section below.
EN Preparation
Summary of Contents for 5059340127514
Page 1: ...5059340127514 CLFLEXDOWN A B Induction Booster Flexi zone Flexi zone Induction Booster...
Page 2: ...Preparation 03 Care and Maintenance 32 EN Contents Installation 19 Use 21...
Page 8: ...05 06 x7 x7 x10 A B C 20mm x2 x1 AF AG DD CC AA AG AG DD AF EN Preparation CC A B C EE JJ...
Page 9: ...07 08 20mm x2 x1 AF AG MGG AA CC DD MGG AA CC BB DD EN Preparation...
Page 11: ...11 12 0 3 X 2 04 X 4 04 X 4 EE EN Preparation 280mm...
Page 12: ...13 W X D x20 15mm x5 x5 EN Preparation W W D CC x2 AR AR 90 AR AR AR 14 AR...
Page 20: ...EN Installation A B RECIRC KIT 1 EN Only for ducted option EN Only for recirculation option 20...