Electrical Requirements
Any permanent electrical installation must comply with the latest I.E.E. Regulations
and local electricity company regulations. For your own safety a qualified electrician or
contractor who is on the roll of the National Inspection Council for Electrical Installation
Contracting (NICEIC) should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the mains voltage corresponds to the
voltage on the rating plate on the appliance.
Warning!
This appliance must be earthed.
The appliance is supplied with a 3-core mains cable and must be connected to the
electricity supply via a double pole switch having a 3 mm minimum contact gap on each
connector.
For UK only
A Switched Fused Connection Unit to BS 1363 Part 4 is recommended.
The fuse must be rated at 13 Amps.
The wires in the mains lead are coloured in accordance with the following code:
Brown
=
L - Live
Blue
=
N - Neutral
Green and Yellow
=
- Earth
The connection point must be placed in a position adjacent to the appliance so as to be
readily accessible for an engineer in the event of a breakdown.
Disconnect the appliance from the mains supply before carrying out any kind of
maintenance or cleaning.