Using and Resetting the Counter
• Every time the foot pedal is pressed the cycle count will be displayed on the digital
display windows.
• The time setting for the inflation cycle will disappear once the foot pedal has been
pressed. To verify or change the time setting for the inflation cycle, press any of the arrow
buttons on the control panel once.
• The balloon time setting will be displayed on the digital window. Press the Reset button
in the center of the control panel to set the counter back to zero.
If you detect balloons are not being identically sized from both outlets, follow the instructions below to recalibrate your inflator.
NOTE:
Always use 11
"
balloons when comparing sizes. Once the desired size is
reached, all balloon sizes should consistently inflate to the same size when the digital
settings are changed. For time settings, refer to the Size Setting Chart on the front of
this instruction sheet.
To increase
balloon size
To decrease
balloon size
Determine which outlet is not
inflating to the correct size and
remove the detachable friction
fit outlet from the filling port
by pulling upward and gently
twisting as needed.
To increase the size of the balloon,
turn the tool counter clockwise in
quarter turn increments
. To
decrease the size of the balloon,
turn the tool clockwise in quarter
turn increments. IMPORTANT:
Be careful not to over tighten
the setting. STOP turning the tool
clockwise if you feel resistance on
the tool.
Remove the allen wrench and
press the detachable friction
fit outlet back onto the filling
port by pushing downward and
gently twisting as needed. Inflate
two balloons to compare sizes.
Repeat steps 1 through 3 until
both balloons are identically
sized.
Insert the allen wrench into the filling outlet. Gently
apply downward pressure and slowly rotate the
tool until you hear a “click” sound and feel the tool
become fully engaged in the outlet.
Calibration Instructions
Inflating Balloons with the Precision Air Inflator
Place the Extension Tip over the Latex Outlet when
inflating 5
"
balloons. Slide the neck of the balloon all
the way down on the Extension Tip until the neck is
touching the base.
To achieve consistent results, do
not cover the opening of the Extension Tips with
your fingers.
For 9" balloons and larger, remove the Extension
Tip and roll the neck of the balloon over the Latex
Outlet.
To achieve consistent results, do not cover
the opening of the outlet with your fingers.
Tap the foot pedal to begin the inflation
cycle. When the system automatically
shuts-off, remove the balloons from the
outlets without allowing any of the air to
escape, and tie. Wait 3 seconds for the
auto exhaust vent to shut off before the
next cycle.
1
1
2
2
3
3
4
A 3/8 (9mm) allen wrench is required for calibrating the Precision Air.