background image

On/Off

LED Mode Indicator

1

2

3

4

Select and set the proper mode by

pressing the mode setting button.

The LED display will indicate which

mode the Dual Split-Second Sizer is

in. (See Chart Below)

Setting the Dual Split-Second Sizer

Mode Settings

LED will light to indicate which mode
the Dual Split-Second Sizer is set to.
(see photo #2)

Place the balloon over the inflating

outlet. Slightly roll the neck of the

balloon over the inflating tip. This

will insure the gas enters the center

of the balloon and the round shape

of the balloon is maintained during

the inflation process.

Tap the foot pedal to begin the

inflation cycle. When the system

automatically shuts-off, remove the

balloons from the outlets without

allowing any of the gas to escape.

Reference the size setting chart below and

set the Dual Split-Second Sizer to the

appropriate time and pressure settings. To

adjust the inlet pressure, pull the knob up to

release it and turn it clockwise to increase

the pressure and speed of inflation. This will

increase the size of the balloon. To decrease

the size of the balloon and speed of

inflation, turn the knob counter-clockwise.

Press the knob down to lock it in place after

making the desired setting.

2

6.6 Seconds

6.9 Seconds

80 PSI

80 PSI

14”

16”

Dual Split-Second Sizer Settings Chart

BALLOON

SIZE

4.2 Seconds

4.4 Seconds

80 PSI

80 PSI

60/40 HELIUM/AIR OUTLET

1 Outlet

2 Outlets

60/40 Helium/Air Outlet Settings

The following settings should be used as guidelines for the using

the optional 60/40 Helium/Air Outlet with the Dual Split-Second

Sizer. The 60/40 Helium/Air Outlet is recommended for use with

14” or larger balloons. (See back page for details).

BALLOON

SIZE

5”

N/A

N/A

N/A

N/A

0.6 Seconds 0.8 Seconds

70 PSI

70 PSI

1.1 Seconds 1.4 Seconds

70 PSI

70 PSI

2.0 Seconds 2.7 Seconds

70 PSI

70 PSI

3.2 Seconds 4.1 Seconds

70 PSI

70 PSI

0.2 Seconds 0.3 Seconds

90 PSI

75 PSI

1.5 Seconds 1.9 Seconds

75 PSI

75 PSI

2.8 Seconds 3.7 Seconds

75 PSI

75 PSI

5.2 Seconds 6.5 Seconds

75 PSI

75 PSI

8.3 Seconds 9.9 Seconds

75 PSI

90 PSI

0.3 Seconds 0.5 Seconds

75 PSI

75 PSI

1.9 Seconds 3.1 Seconds

75 PSI

75 PSI

3.4 Seconds 5.5 Seconds

75 PSI

75 PSI

6.3 Seconds 9.9 Seconds

90 PSI

90 PSI

N/A

N/A

N/A

N/A

9”

11”

14”

16”

HELIUM

1 Outlet

2 Outlets

1 Outlet

2 Outlets

NITROGEN

1 Outlet

2 Outlets

AIR COMPRESSOR

The following settings should be used as guidelines for the Dual Split-Second Sizer. Please note that size settings will vary based on user preference, balloon color

and manufacturer. To adjust the size of balloon to your individual preference it is necessary to inflate test balloons.

PSI SETTINGS

refer to the gauge located on

adjustable regulator at the back of Dual Split-Second Sizer. This controls the speed of the inflation cycle.

SECONDS SETTINGS

refers to the tenth of a second

increment readouts on digital display(s) on Dual Split-Second Sizer.

Important:

To ensure consistent balloon sizing when using helium or nitrogen, it is necessary to check the size of the balloons every 1/3 of a cylinder of

gas. If necessary, increase the size of the balloon by either increasing the size setting or the inlet pressure.

MODE 1

Use Mode 1 to inflate two

balloons to the same size.

Timer A

Timer B

Left Outlet

Right Outlet

ON

OFF

ON

ON

MODE 2

Use Mode 2 to inflate one balloon

or when using an accessory outlet.

Timer A

Timer B

Left Outlet

Right Outlet

MODE 3

Use Mode 3 to inflate two

balloons to different sizes.

Timer A

Timer B

Left Outlet

Right Outlet

ON

OFF

ON

OFF

ON

ON

ON

ON