7.  Registering the smoke detector with the base 

station of the type „Homeguard MS8000“ 

 
 

Carry out the following steps: 
(Every time you press a key you hear a short confirmation beep) 

 
1.

 

Open the lid of the Homeguard. 

 

2.

 

Key in your PIN-code (factory default: 0000). If the code is correct you 

will hear a longer confirmation beep. The green LED should start to flash. 
(Otherwise you did not key in the correct PIN-code.) 

 

3.

 

Press the 1 key to set the  Homeguard to learning-mode. 

 

4.

 

Place the battery (9V)  in the correct polarity in the battery holder of the 
smoke detector. The smoke alarm sends a radio signal to the base 

station: The LED on the sensor illuminates briefly, the base station emits 
a short signal tone as confirmation of reception.

 

 

5.

 

(If you are using more than one smoke detector you have to follow these 
steps only once.) 

 

6.

 

Press the 1 key again to leave the learning-mode. 

 
Now the smoke detector is registered and ready to be used.  
 
In the case of a fire emergency the smoke detector sends the alarm signal to 

the Marmitek alarm installation (it does not matter  whether the base station 
is set to arm or disarm. The alarm will be triggered in both cases!) 

Summary of Contents for HOMEGUARD MS8000

Page 1: ... Smoke Detector Type 3 Operating Instructions Version 1 2 For Marmitek alarm installations of the types Homeguard MS8000 Security Systems MS9470 MS9480 Security Systems MS9770 MS9780 Base Stations SC2700 SC2800 ...

Page 2: ...ocessed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged Modifications due ...

Page 3: ...nces 5 4 Installation places 5 5 Installation 8 6 Registering the smoke detector with the base systems stations of the types MS9470 MS9770 MS9480 MS9780 SC2700 SC2800 10 7 Registering the smoke detector with the base station of the type Homeguard MS8000 11 8 Final assembly 12 9 Convia smoke detector technical data 12 ...

Page 4: ... causes the light to be dispersed by smoke particles and picked up by the receiver In contrast to many products on the market no radioactive substance is necessary for the optical smoke detection The smoke detector will impress you owing to the following features Monitoring of rooms for the development of smoke Integrated signal transmitter Alarm transmission even for non activated alarm unit 2 In...

Page 5: ...detectors should be installed in accordance with the NFPA Standard 74 National Fire Protection Association Batterymarch Park Quincy MA 02169 In principle it is advisable to install several smoke detectors in the building and or in the dwelling In any case at least one smoke detector should be installed in each floor of buildings with more than one floor Only like that a punctual and thus effective...

Page 6: ...Page 6 of 12 Recommended best and acceptable locations to mount smoke detectors Locations for placing smoke detectors for single residence with only one sleeping area ...

Page 7: ...Page 7 of 12 Locations for placing smoke detectors for single floor residence with more than one sleeping area Arrangement in a building with many floors ...

Page 8: ...rates Ensure that the smoke detector is not installed directly on or in the vicinity of large metal objects as they can affect the radio range 5 Installation Please follow these steps to install the Convia smoke detector At the place where you are going to install the detector draw a horizontal line six inches long Remove the mounting bracket from your unit by rotating it counterclockwise Place th...

Page 9: ...l outward on the detector to make sure it is securely attached to the mounting bracket Do not insert the battery at this stage 9V Please follow the steps of the next chapter before you insert the battery How to install the battery The smoke detector requires an alkaline battery Match terminals on the end s of the battery with opposite terminal connectors on the detector Be sure to insert the alkal...

Page 10: ...est button on the detector to trigger the alarm The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base station emits a short signal tone as confirmation of reception 4 If you are using more than one smoke detector you have to follow these steps only once 5 Reset the mode switch to the RUN1 or RUN2 position Zone indicators go out Now the smoke de...

Page 11: ...Place the battery 9V in the correct polarity in the battery holder of the smoke detector The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base station emits a short signal tone as confirmation of reception 5 If you are using more than one smoke detector you have to follow these steps only once 6 Press the 1 key again to leave the learning mode ...

Page 12: ...al data Frequency 433 92 MHz Modulation AM Range Up to 30 meters Free field In combination with Homeguard the range is reduced Alarm 85 dB Power supply 9V Blockbattery Alkaline Type Operating temperature 10 to 45 degrees Celsius Air moisture 95 rel air moisture 2003 Convia GmbH Burgemeisterstr 34 12103 Berlin GERMANY http www convia gmbh de Please report manual errors to manual convia gmbh de ...