Note: Calibration is automatically performed for all screen types when the screens are fully retracted (or
up).
For screens with doors, semi-automatic calibration is required
—nowhere else.
Directions for Semi-Automatic Calibration (you will need perform this in cases
ONLY
where there is a
door and the door is not currently closed and the screens/masks fully retracted initially upon factory
production)
Directions with only a keypad
Directions with Pilot connected to computer
1
Raise screen to fully retracted position
Raise screen to fully retracted position
2
Raise mask to fully retracted position
Raise mask to fully retracted position
3
With the new keypad (marked 2112 or
BSKP-XXXX) hit the * button until the
second beep occurs. This will send a
CALIBRATE command over the CS-BUS
to the system which will instruct the unit
that all screens and masks are full retracted
and in such position the door is safe to close.
With Pilot running on a computer connected to
the IMC-300MKII BRIC II via ethernet, send
over the command within the TRAFFIC window:
#1.1.0.MOTOR=RETRACT
This sends over the important CALIBRATE
command over the CS-BUS to the system which
will instruct the unit that all screens and masks
are full retracted and in such position the door is
safe to close.