Converging Systems Inc.
Page 11
Rev.5.0.0
LED will indicate the Controller’s status. Please refer to the following two configuration cases below
for the specific information for your installation.
State
If no IP connection is
provided at power-up
If IP connection is provided at power-up
AC power applied
●
Initially, on-board
RED
LED
will flash for 2 seconds
indicating Power ON Self Test
passed.
●
Initially, on-board
RED
LED will remain ON for 2 seconds
indicating Power ON Self Test passed
Waiting to recognize
IP connection
●
GREEN
LED will flash
FAST
indicating that it is searching for
a valid IP connection. In this
case, since no IP connection is
provided, after __ seconds,
LED will switch to
BLUE SLOW
flash which means that
alternative communication
channels can be used to control
device.
●
GREE
N LED will flash
FAST
while a valid IP connections
is being made
Network connection
made
●
N/A in this case
●
Once valid IP connection is made, led will change to
SLOW GREEN
flash
Removal of Network
connection
(
GREEN
LED will continue to Flash
SLOW
LY but
alternative communication channels (RS-232c) can be
used)
Note system is still looking for an IP connection and LEDs
will continue to cycle as described above.
f.
Provided the DIP switches have been set to a valid programmed setting, pressing an appropriate
button on a BSKP-2112 keypad should enable quick testing of the Masking Director System.
g.
Enhanced testing can be performed using the e-Node Pilot application.