background image

INSTALLING THE EXHAUST HOSE

Step 1:

Step 2:

Step 3:

Fit the exhaust hose to the rear

panel outlet by screwing the hose in a
clockwise direction.  Fit the window adaptor
onto the hose by rotating the adaptor in a
clockwise direction.

Screw the round window adaptor

into position on the window attachment with
the screws (4) provided.

Open the window and fit the

adjustable window attachment. Extend the
attachment as required and lock into place
with the screws (2) provided.  Ensure the
outlet is not obscured. The window
attachment can be installed horizontally or
vertically, depending on the window type.

Note!

Note!

The minimum distance required

from the operating air conditioner to
any obstructing objects or walls is
50cm (Fig 6).

Keep the exhaust hose as short and
straight as possible and minimise
kinks.  This will maximise the cooling
performance.

Don

t use extension pieces for the

exhaust pipe as this will reduce the
cooling performance and possibly
result in damage to the air conditioner.

Hot air and possibly mist will be
emitted from the exhaust hose.

It is critical to the cooler

s

performance that the hot exhaust air is
completely removed from the space
being cooled.

5

50cm

6

CP10-12CW1 Portable Refrigerated Air Conditioner

4

Sleep

button

Swing
button

Press to enter the

sleep mode

Press to activate

left/right swing vanes

To avoid damage to the control panel, do not operate with sharp objects.

NOTE!

7

CONTROL PANEL

Press to cycle from

Cooling, Dehumidifying

and Fan modes.

Press to enter the

timer setting mode

and time

Press to turn the

air conditioner on

and off

Press + to increase,

- to decrease the

set temperature

Press to cycle the fan

speed between low

and high

Power ON / OFF

button

Timer Set

button

Mode Select

button

Temperature adjust

buttons

Fan Speed

control button

Mode

Indicator

Fan Speed

Indicator

Water

Full

Indicator

Set Temp

Display

Compressor

On

Indicator

POWER
Indicator

SWING

TIMER

SLEEP

UP

WATER FULL

COMP.

HIGH

LOW

COOL

DEHUM

FAN

DOWN

SPEED

MODE

POWER

SEELEY INTERNATIONAL

OWNER’S MANUAL

5

Summary of Contents for CP10CW1

Page 1: ...English CP10 12CW1 CP10CW1 CP12CW1 OWNER S MANUAL Portable Refrigerated Air Conditioner...

Page 2: ...Waste electrical products must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment CONTENTS Introduction 1 Safety 2 Component locati...

Page 3: ...Convair cooler is a portable air conditioning unit that supplies refrigerated air to a personal area within a room It is not intended to function as a house or room air conditioner Be sure the applia...

Page 4: ...e connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply refer to the rating label located on the back of the unit refer Fig 4 E...

Page 5: ...r Display Panel Control Panel Air Filter Air Filter Drain Air Intake Power Cord Exhaust Air Outlet Exhaust Hose Window Attachment Exhaust Fitting window end Screws 6 Rating Label Cord Storage Hooks CO...

Page 6: ...achment can be installed horizontally or vertically depending on the window type Note Note The minimum distance required from the operating air conditioner to any obstructing objects or walls is 50cm...

Page 7: ...me Press to turn the air conditioner on and off Press to increase to decrease the set temperature Press to cycle the fan speed between low and high Power ON OFF button Timer Set button Mode Select but...

Page 8: ...batteries Remove the batteries and replace with new ones If this does not solve the problem contact your nearest service centre for advice AAA making sure the and are matching the compartment marking...

Page 9: ...ler is plugged in and switched on Step 2 Step 3 Cooling mode Dehumidifying mode Fan mode Step 4 Step 5 Press the ON OFF button on the remote control or ON OFF button on the control panel to start the...

Page 10: ...e cooler must be plugged in and ready to operate With the air conditioner ON press the TIMER button on the remote control or control panel The control panel display will flash and show the time settin...

Page 11: ...ever use aggressive chemicals spirits detergents chemically treated cloths or other cleansing solutions These substances could possibly damage the cabinet Use a vacuum cleaner or tap the filter lightl...

Page 12: ...cool as it once was Are the filters dusty or dirty restricting the airflow Is the air inlet or outlet blocked Is the room temperature below the set temperature The air conditioner is too noisy Is the...

Page 13: ...on Cooling Capacity Watts Air Flow Volume m hr 3 Power Supply Rated Input Power Watts Fuse Type Refrigerant Type Charge kg Water Ingress Protection Rating Weight kg Dimensions mm width depth height CP...

Page 14: ...with the instructions in the Owner s Manual The addition of any third party device or the removal or the alteration of any of our components will void this warranty In addition the warranty granted un...

Page 15: ...iability under this warranty is limited to the extent permitted by law That is to the extent that it is fair and reasonable if the Goods are not of a kind ordinarily acquired for personal domestic or...

Page 16: ...0 526 410 seeleyinternational com It is the policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult wit...

Reviews: