background image

As a policy of continual product improvement, this manual, its contents and specifications are subject to change without notice.

SEELEY INTERNATIONAL - CLIMATEMASTER

PORTABLE AIR CONDITIONER

ClimateMaster CM12RW

ClimateMaster CM12RCW
ClimateMaster CM12RCS

Personal Cooling

Personal Cooling & Heating

3,500 (12,000 Btu/hr)

3,500 (12,000 Btu/hr)

-

3,500 (12,000 Btu/hr)

2.5

2.5

310

310

£

52

£

52

220-240 V ~, 50 Hz

220-240 V ~, 50 Hz

1300

1350

6

6.2

3.15 A / 250V

3.15 A / 250V

R407C / 0.61

R407C / 0.61

2.7

2.9

0.6

0.7

IPX0

IPX0

40

40

445 / 350 / 870

445 / 350 / 870

Model

Function

Cooling Capacity (Watts) †

Heating Capacity (Watts) †

Dehumidifying Capacity (L/hr)

Air Flow Volume (m / hr)

3

Noise Level - Sound Pressure (dB(A))

Power Supply

Input Power (Watts)

Input Current (Amperes)

Fuse Type

Refrigerant Type / Charge (kg)

High Side Pressure - Maximum (MPa)

Low Side Pressure - Maximum (MPa)

Water Ingress Protection Rating

Weight (kg)

Dimensions (mm)
(width / depth / height)

Based on manufacturer's test results using the Air Enthalpy method

SPECIFICATIONS

12

3-PIN

SUPPLY

PLUG

- - - REVERSE CYCLE ONLY

L

N

PIPE
ROOM

COMPRESSOR

R

C

WIRING DIAGRAM

S

CONTROL PANEL

7 WIRE
LOOM

CONDENSOR

FAN

8 WIRE
LOOM

EVAPORATOR

FAN

PUMP

4

WAY

REMOTE

CONTROL

SENSOR

3 WIRE
LOOM

SWING

MOTOR

(HORZ)

5 WIRE
LOOM

SWING

MOTOR

(VERT)

5 WIRE
LOOM

Summary of Contents for ClimateMaster CM12RCS

Page 1: ...Instruction Manual ClimateMaster CM12RW CM12RCW CM12RCS ClimateMaster Portable Refrigerated Air Conditioner...

Page 2: ...cts must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment Please read these instructions prior to using the appliance and save the...

Page 3: ...ble for their safety Children should be supervised to ensure that they do not play with the appliance Do not place anything through the ventilating slots Your Convair cooler is a portable air conditio...

Page 4: ...ety cont Caution before connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply refer to the rating label located on the back of...

Page 5: ...Control panel Air Filter Air Intake Power cord Air Intake Air Intake Exhaust Air Outlet Drain 3 4 Rating Label OSC Mode Temp Speed On Off Timer OSC Remote Control Exhaust Hose Window Kit Exhaust Fitt...

Page 6: ...ow and fit the adjustable window attachment Extend the attachment as required and lock into place with the wing nut Ensure the outlet is not obscured The window attachment can be installed horizontall...

Page 7: ...zontal Swing Vane button Vertical Swing Vane button Mode Select button Press to turn the air conditioner on and off Press to cycle the fan speed between low medium and high Press to enter the timer se...

Page 8: ...batteries If there is no display or only part display remove the batteries and replace with new ones If this does not solve the problem contact your nearest service centre for advice AAA making sure...

Page 9: ...mode automatic selection of operating mode reverse cycle heating Fan only operation no cooling refrigerated cooling refrigerated moisture removal from the air r s The temperature set range is 16 C 31...

Page 10: ...adjust the time in 0 5 hour increments from 0 5 12 hrs Fig 14 shows the cooler will turn off after 2 5 hrs When the air conditioner is working only the TIMER OFF can be set When the air conditioner i...

Page 11: ...in hours will be displayed Adjust by pressing the TEMP TIMER button to increase or decrease in 0 5 hr increments To cancel the TIMER change the SET TIME to 0 0 h after 2 seconds the SET TIME will dis...

Page 12: ...ate the air conditioner without the filter Use a soft damp cloth to wipe the body clean Never use aggressive chemicals spirits detergents chemically treated cloths or other cleansing solutions These s...

Page 13: ...t air needs to be completely removed from the room The air conditioner is not as cool as it once was Is the filter dusty or dirty restricting the airflow Is the air inlet or outlet blocked Is the room...

Page 14: ...350 870 Model Function Cooling Capacity Watts Heating Capacity Watts Dehumidifying Capacity L hr Air Flow Volume m hr 3 Noise Level Sound Pressure dB A Power Supply Input Power Watts Input Current Am...

Page 15: ...NOTES 13...

Page 16: ...t is the policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specif...

Reviews: