PRODUCT

Product type 

Stove lit with solid biofuels 

Type designation 

Contura 330G 

Manufacturing number 

See rating plate on the stove 

Intended area of use 

Heating of rooms in residential buildings 

Fuel 

Wood

MANUFACTURER

Name 

NIBE AB / Contura 

Address 

Box 134, Skulptörvägen 10 

 

SE-285 23 Markaryd, Sweden

CHECKS

According to AVCP 

System 3 

European standard 

EN 13240:2001/A2:2004/AC:2007 

 

Test institute 

Rein-Ruhr Feuerstätten Prüfstelle, NB 1625,

 

has checked declared performance and issued test report no. RRF-40 17 4648  

 

Declaration of performance according 
to Regulation (EU) 305/2011

No. C330G-CPR-170824

DECLARED PERFORMANCE

Essential characteristics

Performance

Harmonised technical
specification

Reaction to fire

NPD

Minimum distance to combustible material

Rear: 100 mm
Side: 500 mm  
Other safety distances according to 
the installation instructions

Risk of falling embers

Pass

EN 13240:2001/A2:2004/AC:2007

Emissions from combustion

CO           0,07 %

Surface temperatures

Pass

Cleaning options

Pass

Mechanical durability

Pass

Emissions of hazardous substances

Pass

Nominal output

7 kW

Efficiency

77 %

Flue gas temperature in connector at nominal 
output

369°C

The undersigned is responsible for the manufacture and conformity with the declared performance.

Niklas Gunnarsson,

 

Business area manager NIBE STOVES

 

Markaryd, 1st September 2017

Summary of Contents for C330G

Page 1: ...C330G www contura eu...

Page 2: ...nces 16 Distanze di sicurrezza 25 Installasjonsavstand 10 Installationsafstand 19 Installatieafstand 28 Prestandadeklaration 5 D claration des performance 14 Suoritustasoilmoitus 23 Leistungsdeklarati...

Page 3: ...erneath of the stove To determine correct amount of air supply use current edition of Building Regulations The connector for the combustion air has an external diameter of 65 mm When duct routing furt...

Page 4: ...tible parts of the building or interior decoration must be at least 1 4 m If the appliance will be placed on the floor it must stand on a constructional hearth which meet the building regulations and...

Page 5: ...ulation EU 305 2011 No C330G CPR 170824 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire NPD Minimum distance to combustible material Rear...

Page 6: ...If the stove needs to be laid down for it to be moved loose components should be removed A description of how to remove hearth cladding can be found at the end of these instructions 1 Fire bricks Verm...

Page 7: ...nstein Bakmontering til murt skorstein Raccordement par l arri re une chemin e de ma onnerie Rear connection to a masonry chimney Tilslutning bagud til muret skorsten Liit nt taaksep in muurattuun sav...

Page 8: ...rdement la chemin e par le haut Top connection to the chimney The hot air grille must be installed before chimney top connection Toptilslutning til skorsten Varmluftristen skal v re monteret f r skors...

Page 9: ...Tilbeh r Tilluftsstuss Arriv e d air Accessoires Manchon d arriv e d air Supply Accessories Air inlet Forbr ndingsluft Ekstraudstyr Luftindsugningsstuds Tuloilma Lis varusteet Tuloilmaliit nt Aliment...

Page 10: ...u ildstedsbekledningen Vermikulitt Voici comment d monter l habillage du foyer Vermiculite How to remove the hearth surround Vermiculite S dan afmonterer du ovnbekl dningen Vermiculite N in irrotat tu...

Page 11: ...35 8 7 5 6...

Page 12: ...and operated in accordance with these instructions and when fitted with a permanent stop to prevent clo sure of the air control unit beyond 31 open position Mandatory for smoke control areas The perm...

Page 13: ...37 1 2 Alt 1...

Page 14: ...38 1 2 3 Alt 2...

Page 15: ...39 M5x8 T25 4 5...

Page 16: ...40 6 7...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...811305 IAV SE EX C330G 2 2018 01 09 NIBE AB Box 134 285 23 Markaryd Sweden www contura eu...

Reviews: