Contura C i10 Installation Instructions Manual Download Page 8

GB

24

Self-closing hatch

The insert can be supplied with a self-closing hatch. First open 
the hatch according to section 

“Cleaning the hatch glass”,

 then 

remove the four screws to release the Upper member. Remove 
the two screws that hold the spring assembly, install the weight 
to the upper member and reinstall the spring assembly in the 
upper screw holes. Reinstall the Upper member using the four 
screws. The insert can now be supplied with the self-closing 
hatch.

Installing removable parts

Removing the hatch from the insert facilitates the installation 
of the hearth surround on the I 20. If the insert is recessed, 
removal of the hatch is made easier if the damper knob is 
removed. After the catches have been opened the hatch will fall 
forward to a limit position. Now lift the hatch and at the same 
time move it to the left so that the right side releases from its 
mounting, then tilt the hatch out. Assembly takes place in the 
reverse order. 

2

1

Spring assembly

Weight

Upper member

PRIOR TO INSTALLATION

Summary of Contents for C i10

Page 1: ...Installation Instruction C i10 C i20 www contura eu...

Page 2: ...el type Wood logs Wood logs flue gas temperature 265 C 280 C energy efficiency 81 81 emission of cO 0 09 0 07 Installation distances See installation instructions appendix Lighting and installation in...

Page 3: ...extremely hot and can cause burn injuries if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Py...

Page 4: ...least 300 mm in front and 100 mm along each side of the hatch opening A painted metal or toughened glass hearth plate is available as an accessory Technical Data Model i10 i20 Power output 6 12 kW 6 1...

Page 5: ...ortant dimensions C i10 1315 10 1230 10 1070 10 120 10 450 320 10 515 200 40 10 Air inlet 100 200 785 680 1535 10 1450 10 1290 10 5 670 320 10 515 200 40 10 Air inlet 100 200 685 580 C i20 IMPORTANT D...

Page 6: ...and the loose parts can be removed Before moving the insert from the pallet transport lock the hatch again by reinstalling the screws on the counterweight The insert is secured to the pallet via two r...

Page 7: ...are lubricated at the factory with special grease that can withstand high temperatures This type of grease is usually difficult to find on the market and we recommend contacting a Contura dealer to or...

Page 8: ...The insert can now be supplied with the self closing hatch Installing removable parts Removing the hatch from the insert facilitates the installation of the hearth surround on the I 20 If the insert...

Page 9: ...finally install the right back section and side Smoke baffle PRIOR TO INSTALLATION Prior to positioning the smoke baffle on top of the hearth surround s sides The diffuser must be positioned up insid...

Page 10: ...the outer wall of the room where the stove is to be placed The amount of combustion air that is used for combustion is approx 30 m3 h Some installation alternatives are shown to the right The air duct...

Page 11: ...room if the insert is lit with the hatch open The condition for connecting to a 150 chimney is that the insert must only be lit with the hatch closed Rear connection to a masonry chimney Mark out the...

Page 12: ...ector ensure that gasket does not move out of position When the insert is in position seal the connection pipe and wall connector well use heat resistant sealant if necessary Reinstall the top and rea...

Page 13: ...above the convection exhaust This is to prevent hot air collecting in the recess closest to the ceiling The seal must a maximum of 100 mm above the convection exhaust s upper edge and must be made up...

Page 14: ...0 Wall of non combustible material that is not in contact with combustible material and therefore has no minimum thickness requirement Recess example Chimney breast 20 100 Area ut min 600 cm 2 Area in...

Page 15: ...20 550 max 100 20 100 Area ut min 600 cm2 Area in min 600 cm2 I 10 min 2100 I 20 min 2300 min 700 100 20 100 Area ut min 600 cm2 Area in min 600 cm2 I 10 min 2200 I 20 min 2400 Heat Shield Area min 60...

Page 16: ...ontura reserves the right to change colours materials dimensions and models at any time without special notice Your dealer can give you the most up to date information Stoves shown in brochures may ha...

Reviews: