1

100

GB

FACTS

 Effect 

3-7 kW

Nominal effect 

5 kW

Efficiency 

up to 80%

Model 

 790K 

Height (mm) 

 

1593 

Width (mm) 

 

556 

Depth (mm) 

 

407 

Weight (kg) 

 

170

Stone heat tank (kg) 

 

110 

Type approved in accordance with:

European standard EN-13240 
Swedish type approval SITAC SC 0307-11
Norwegian standard NS 3059, SINTEF - 110-0354
German standard DIN Plus, RRF - 40 12 3047

Prior to installation

If the insert needs to be put down 
to be moved, loose components 
should be removed. When the stove is 
installed reinstall the components in 
reverse order.

1  Fire bars
2  Grate disc
3  Heat deflector
4 Firebricks

Installation by authorised 
technician 

This manual contains instructions about 
how the stove must be assembled and 
installed. To ensure the function and safety 
of the stove, we recommend that the 
installation is carried out by an authorised 
technician. Contact one of our dealers who 
can recommend suitable fitters. 

Building application

These main instructions may give guidance 
which would contravene national building 
regulations. Please refer to supplementary 
instructions or ask your local authority for 
advice regarding building regulations.
Before installing a stove or erecting a 
chimney it is necessary for you to make 
a building permission application to your 
local authority.

Structural support

Check that the wood joists are strong 
enough to bear the weight of the stove and 
chimney. The stove and chimney can usually 
be placed on a normal wooden joist in a 
single occupancy house, if the total weight 
does not exceed 400 kg.

Floor plate

Due to the risk of falling embers, a 
flammable floor must be protected by a 
hearth plate. It must extend 300 mm in 
front of the stove and 100 mm on each side 
of the stove, or have a 200 mm extension 
on each side of the opening. The hearth 
plate can consist of natural stone, concrete, 
metal plate or glass. A painted metal 
or glass hearth plate is available as an 
accessory for these models. 

Important to remember!

Technical details

Summary of Contents for C 790K

Page 1: ...www contura eu C 790K Installation instructions...

Page 2: ...ECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 400 mm to side Other safety...

Page 3: ...as this will affect the routines for regular chimney sweeping services List of Contents Technical details 100 Prior to installation 100 Connection to chimney 101 Supply of combustion air Option 102 I...

Page 4: ...suitable fitters Building application These main instructions may give guidance which would contravene national building regulations Please refer to supplementary instructions or ask your local autho...

Page 5: ...of the connection sleeve is 150 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum...

Page 6: ...and a correspondingly larger wall vent must be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in be...

Page 7: ...combustible walls is used The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m The dimension diagrams only show the minim...

Page 8: ...A DIUM No 7 CH RO ME x 5 x 5 10 10 VANADIUM No 7 CHROME 1 3 2 10 10 VANA DIUM No 7 CHROME 104 GB ASSEMBLY Installing heat tank stone If the stove cannot be equipped with the heat tank stone advance to...

Page 9: ...4 6 5 105 GB ASSEMBLY...

Page 10: ...8 7 9 90 10 2 3 4 1 2 1 106 GB ASSEMBLY...

Page 11: ...107 GB ASSEMBLY...

Page 12: ...2 1 10 10 VANA DIUM No 7 CHROME 108 GB ASSEMBLY Installing suspension profiles...

Page 13: ...3 4 109 GB ASSEMBLY...

Page 14: ...6 5 10 10 VAN ADI UM No 7 CH RO M E 2 1 90 110 GB ASSEMBLY...

Page 15: ...7 8 111 GB ASSEMBLY...

Page 16: ...2 3 mm 1 2 3 4 3 mm 112 GB ASSEMBLY Installing tiles...

Page 17: ...5 7 6 113 GB ASSEMBLY...

Page 18: ...8 9 114 GB ASSEMBLY...

Page 19: ...1 2 3 4 115 GB ASSEMBLY Installing heat tank stone on top...

Page 20: ...nal inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before light...