Connection to chimney
Rear connection to a masonry chimney
Top connection to the chimney
Make sure that the connector
gasket does not work loose when
the connection pipe is placed
on the connector. If further
sealing material is required, heat-
resistant sealant may be used.
The back panel must be installed on the stove before the
stove is connected at the rear.
The hot air grille must be installed before chimney
top connection.
• The stove meets the requirements for connecting to chimneys
dimensioned for 350°C flue gas temperature.
• The external diameter of the connection sleeve is 150 mm.
• The stove requires a draft in the chimney of at least –12 Pa. The
draft is affected both by the length and area of the chimney, and
by how well sealed it is. The minimum recommended chimney
length is 3.5 m and suitable cross sectional area is 150-200 cm²
(140-160 mm in diameter).
• A flue with sharp bends and horizontal routing reduces the
draught in the chimney. The maximum horizontal flue is 1 m, on the
condition that the vertical flue length is at least 5 m.
• It must be possible to sweep the full length of the flue and the
soot doors must be easily accessible.
• Carefully check that the chimney is sealed and that there is no
leakage around soot doors and flue connections.
In the bag with these installation instructions
are two wing screws for the lid.
CHIMNEY
Summary of Contents for C 630
Page 1: ...C 630 www contura eu Installation instruction...
Page 8: ...56 GB...
Page 10: ...6 7 58 GB ASSEMBLY...
Page 11: ...2 1 8 9 59 GB ASSEMBLY If the stove will not be equipped with a heat tank skip step 9...
Page 15: ......