Contura C 630 Installation Instruction Download Page 6

Ø 

ca 180 mm

Ø 

ca 180 mm

!

1

4

5

6

2

3

54

GB

Connection to chimney

Rear connection to a masonry chimney

Top connection to the chimney

Make sure that the connector 
gasket does not work loose when 
the connection pipe is placed 
on the connector. If further 
sealing material is required, heat-
resistant sealant may be used. 

The back panel must be installed on the stove before the 
stove is connected at the rear.

The hot air grille must be installed before chimney 
top connection. 

•  The stove meets the requirements for connecting to chimneys 

dimensioned for 350°C flue gas temperature. 

•  The external diameter of the connection sleeve is 150 mm. 
•  The stove requires a draft in the chimney of at least –12 Pa. The 

draft is affected both by the length and area of the chimney, and 
by how well sealed it is. The minimum recommended chimney 
length is 3.5 m and suitable cross sectional area is 150-200 cm² 
(140-160 mm in diameter). 

•  A flue with sharp bends and horizontal routing reduces the 

draught in the chimney. The maximum horizontal flue is 1 m, on the 
condition that the vertical flue length is at least 5 m. 

•  It must be possible to sweep the full length of the flue and the 

soot doors must be easily accessible.

•  Carefully check that the chimney is sealed and that there is no 

leakage around soot doors and flue connections.

In the bag with these installation instructions
are two wing screws for the lid.

CHIMNEY

Summary of Contents for C 630

Page 1: ...C 630 www contura eu Installation instruction...

Page 2: ...LARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 570 mm to side Other safety di...

Page 3: ...stove in the lighting instructions NOTE Report the installation of a stove to your local authority The owner of the house is personally responsible for ensuring compliance with the mandatory safety r...

Page 4: ...able fitters Building permission These main insructions may give guidance which would contravene national building regulations Please refer to supplementary instructions or ask your local authority fo...

Page 5: ...er to the particular manufacturer s installation instructions Observe the safety distance to combustible material required by the steel flue WHEN INSTALLING TURNTABLE OPTION the following installation...

Page 6: ...of the connection sleeve is 150 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimu...

Page 7: ...as the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in between the pipe and the wall or floor is sealed using jointing compo...

Page 8: ...56 GB...

Page 9: ...2 5 3 4 1 57 GB Installing C 630 ASSEMBLY If the stove will not be equipped with a heat tank skip steps 3 5...

Page 10: ...6 7 58 GB ASSEMBLY...

Page 11: ...2 1 8 9 59 GB ASSEMBLY If the stove will not be equipped with a heat tank skip step 9...

Page 12: ...11 12 10 60 GB ASSEMBLY With heat tank Install hot air grate with damper function Without heat tank Install standard hot air grate...

Page 13: ...stallation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time Final inspection of the installation Position the...

Page 14: ...ve the hearth surround Vermiculite Handle the vermiculite with care Lift the smoke baffle with one hand whilst removing the sides pieces Reinstall in reverse order How to remove the heat deflector REM...

Page 15: ......

Page 16: ...5 23 Markaryd Sweden www contura eu Contura reserves the right to change colours materials dimensions and models at any time without special notice Your dealer can give you the most up to date informa...

Reviews: