GB
70
HK
HK
40 mm
HK
40 mm
HK
40 mm
Knockout
To insert the combustion air hose, tap out the knockout from the
floor panel and leg using a hammer, remember to protect the
floor.
Supply of combustion air
Combustion air can be provided directly via a duct from
outside, or indirectly via a vent in the outer wall of the room
where the stove is placed. The amount of combustion air
that is used for combustion is approx. 25 m3/h.
Some installation alternatives are shown to the right.
The air duct connector on the stove has an external diam-
eter of Ø64 mm.
In hot areas, the duct has to be insulated with 30 mm
mineral wool covered with a moisture barrier (plastic). It is
important that the lead-in, between the pipe and the wall (or
floor), is sealed using jointing compound. When duct routing
for further than 1 m, the pipe diameter must be increased
to 100 mm and a correspondingly larger wall vent must be
selected.
A 1 m length of condensation-insulated ducting for combus-
tion air is available as an accessory.
SUPPLY AIR/ACCESSORY