Eldstadsbeklädnad

Rosterreglage

Asklåda

Förbränningsluftsreglage

Brasbegränsare

HANDÖL

In accordance with standards below
marking was affixed:
European Standard:
SE Quality Certification, P-marked:
NO Standard NS 3059:
DE and AT Standard DIN 18.891 and
Art 15a B-VG:
Type:
Nominal Output:
Fuel:
Minimun draught:
Flue gas temerature:
Energy efficiency:
Emission of CO in cumbustion products:
Distance to cumbustible wall (mm):

Follow the user’s instructions and use only recomended fuel

NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN

2007
EN 13240
Cert no 0112/07
SINTEF 110-0275

RRF-40 07 13 90

Handöl 31/31A/32/32A

5 kW
Wood
12 Pa
280°C
78%
0,14%
Behind 150
Beside 450 
Corner 150

HANDÖL

NIBE AB SE-85 21 Markaryd Sweden

Type:

Production no.

50-series
7090300236

Output 

3-7 kW

Nominal effect 

5 kW

Efficiency  

80%

Model 

  32 32A 

Weight (kg) 

 

128 

128 

Width (mm) 

 

480 

480 

Depth (mm) 

 

450 

450

Height (mm) 

 

1025  1025 

Installation by authorised 
technician 

This manual contains instructions about 
how the stoves must be assembled and 
installed. To ensure the function and 
safety of the stove, we recommend 
that the installation is carried out by an 
authorised technician. Contact one of 
our dealers who can recommend suitable 
fitters. 

Building permission

These main instructions may give 
guidance which would contravene national 
building regulations. Please refer to 
supplementary instructions or ask your 
local authority for advice regarding 
building regulations.
Before installing a stove or erecting a 
chimney it is necessary for you to make 
a building application permission to your 
local authority.

Structural support

Check that the wood joists are strong 
enough to bear the weight of the stove 
and chimney. The stove and chimney can 
usually be placed on a normal wooden 
joist in a single occupancy house, if the 
total weight does not exceed 400 kg.

Floor plate

Due to the risk of falling embers, a 
flammable floor must be protected by 
a hearth plate. It must extend 300 mm 
in front of the stove and 100 mm on 
each side of the stove, or have a 200 mm 
extension on each side of the opening. 
The hearth plate can consist of natural 
stone, concrete, metal plate or glass. 
A painted metal or glass hearth plate 
is available as an accessory for these 
models. 

Important to remember!

Technical details

Type approved in accordance with:
European standard EN-13240 
Swedish environmental and quality labelling, 
P-labelling cert. no. 0112/07
Norwegian standard NS 3059,
SINTEF 110-0275
German standard DIN 18.891,
RRF-40 07 13 90

Rating plate

Combustion air control

Ash-pan

Hearth cladding

Grate control

Fire bars

FACTS

Summary of Contents for C 32

Page 1: ...Installation Instructions C 32 C 32A www contura eu...

Page 2: ...instructions Niklas Gunnarsson Business area manager NIBE STOVES Manufacturer s declaration The stove is approved by the Swedish National Testing and Research Institute SP SITAC and fulfils the appli...

Page 3: ...tions carefully before installation Read how to best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cau...

Page 4: ...uitable fitters Building permission These main instructions may give guidance which would contravene national building regulations Please refer to supplementary instructions or ask your local authorit...

Page 5: ...ection B height from floor to c c smoke outlet rear C distance from back to smoke outlet rear D height from floor to air inlet E distance from back to c c air inlet F distance from back to c c hole in...

Page 6: ...rox 25 m3 h Some installation alternatives are shown to the right The air duct connector on the stove has an external diam eter of 64 mm In hot areas the duct has to be insulated with 30 mm mineral wo...

Page 7: ...rated above Self closing door The stove is equipped with a spring to close the door auto matically The spring is situated above the heat deflector The closing force of the hatch can be adjusted by mov...

Page 8: ...himney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommended chimney length is 3 5 m and suitable cross sectional area...

Page 9: ...lled before chimney top connection Sweeping When sweeping the smoke baffle must be removed on the Contura 30 series this can be done by lifting the smoke baffle and removing the side piece Lift the sm...

Page 10: ...is assembled It is important to remove all the protective plastic Ensure that your hands are clean to avoid leaving marks on the aluminium sides Cleaning Cleaning must always be carried out with care...

Page 11: ...10 VAN ADI UM No 7 CH RO M E 2 1 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the...

Page 12: ...GB 76 When installing the base the lower knockout in the back panel must always be removed for the supply of convection air Installing accessories Base Base ASSEMBLY 2 1...

Page 13: ...rt the screws in the hole of the rail as illustrated The second screw is inserted in the rear section Hold the rail as far out as possible and angle the front section downwards whilst you tighten the...

Page 14: ...GB 78 2 3 4 5 ASSEMBLY Adjust the drawer so that it is centrally positioned in relation to the hatch and then tighten the screws...

Page 15: ...GB 79 ASSEMBLY Adjust the pieces with the Allen screws so that they are in line with the hatch Installing accessories Log box Log box...

Page 16: ...4 1 NIBE AB Box 134 SE 285 23 Markaryd Sweden www contura eu Contura reserves the right to change colours materials dimensions and models at any time without special notice Your dealer can provide you...

Reviews: