background image

                                           CONTROLS, INCORPORATED 

C O N T R O L   S Y S T E M S   &   S O L U T I O N S  

 

                                                                                                            

                                                                                                                  - 1 - 

 

TABLE OF CONTENTS 

 

PANEL OPERATION

…………….…………………………………………………………………………………….…………………………….……….

MANUAL OPERATION 

MODULE CONNECTORS

…………………………………………………………………………………………………….………………….……….

PRIMARY 14 PIN MODULE CONNECTOR 
 

ENGINE ALARMS, CODES AND MESSAGES

……………………………………………………………………………........………...

5

 

 

WARNINGS & ALARMS 
ALARM EVENT LOG 
INDICATION LAMPS 

CONTROL PANEL SPECIFIC ALARMS AND SHUT DOWNS

………………………………………….…………..……….

CONTROL PANEL DIGITAL INPUT

…………………………………………………………………………………………………..…………

.8 

DIGITAL FUNCTIONS 

CONTROL PANEL RELAY OUTPUTS

…………………………………………………………………..………………………........................

RELAY FUNCTIONS, POLARITY & INITIAL STATE 

MENU SYSTEM

……………………………………………………………………………………………..……………..……………………………………..

11 

 

MENU ACCESS, EXIT AND NAVIGATION 

 

VIEWING MENUS 

 

CONFIGURATION MENUS 

Summary of Contents for C3M-100

Page 1: ...00 Revision 2 0 ______________________________________________________________________________________________________________________________________ Copyright Controls Inc P O Box 368 Sharon Center...

Page 2: ...4 PIN MODULE CONNECTOR ENGINE ALARMS CODES AND MESSAGES 5 WARNINGS ALARMS ALARM EVENT LOG INDICATION LAMPS CONTROL PANEL SPECIFIC ALARMS AND SHUT DOWNS 6 CONTROL PANEL DIGITAL INPUT 8 DIGITAL FUNCTION...

Page 3: ...CONTROLS INCORPORATED C O N T R O L S Y S T E M S S O L U T I O N S 2 PANEL OPERATION MANUAL OPERATION 1 Engine Start Turn key to CRANK position 2 Engine Stop Turn key to OFF position...

Page 4: ...CONTROLS INCORPORATED C O N T R O L S Y S T E M S S O L U T I O N S 3 MODULE CONNECTORS Primary Connector 14 Pin...

Page 5: ...Pin Function 1 Fuel Solenoid 8 MPU 2 Water Temp 9 Battery Positive 3 Battery Positive 10 Key Auto Detect 4 Auto Crank Signal 11 Switched Power to C3M 5 Preheat Signal 12 Battery Negative 6 N O Relay 1...

Page 6: ...ssage appears on the display identifying the cause ALARM EVENT LOG The Alarm Log creates an entry allowing the service and or operator to view the last 32 events An event is considered either a warnin...

Page 7: ...CONTROLS INCORPORATED C O N T R O L S Y S T E M S S O L U T I O N S 6 INDICATION LAMPS The panel has two lamp indicators Engine Fault Shutdown Lamp Engine Warning Lamp...

Page 8: ...100 PSI Low Oil Press Alarm 10 0 100 PSI Oil Press Alarm Delay 5 0 01 1 40 Sec Temperature Check Run Off Always Run Low Temp Pre Alarm 0 0 300 Deg F Low Temp Alarm 0 0 300 Deg F High Temp Pre Alarm 2...

Page 9: ...GITAL FUNCTIONS The digital inputs can be configured for different uses depending on the application These include the following 1 Alarm Engine shutdown when active with display message as assigned A...

Page 10: ...Positive Initial State Off RELAY FUNCTIONS Available relays can be assigned for different uses a None Assign to none when not used b Throttle B1 Reserved for OEM applications c Throttle B0 Reserved f...

Page 11: ...ill be active during an engine start request and while the engine is running Used to drive the engine s ECU circuit Also active when requesting active and stored J1939 codes k Custom 1 Reserved for OE...

Page 12: ...ts Press UP arrow button and DOWN arrow button to change setting Press ENTER button to make selection brackets disappear Recycle key to the OFF position after changing a setting MAIN MENUS Operation E...

Page 13: ...eck Off Always Run Low Fuel Level Pre Alarm Selection Low Fuel Level Alarm Selection Fuel Alarm Time Delay Selection Oil Pressure Check On Off Selection Low Oil Pressure Pre Alarm Selection Low Oil Pr...