MegaChlor Operation (cont.)

MegaChlor Operation (cont.)

Selecting the Right Power Level

Selecting the Right Power Level

Selecting the right power level may require some testing, since every pool and spa is different, and there 

Selecting the right power level may require some testing, since every pool and spa is different, and there 

are a variety of factors that can affect what level would be best for you and your pool or spa. Here are 

are a variety of factors that can affect what level would be best for you and your pool or spa. Here are 

some examples:

some examples:

• •  Frequency of pool/spa use

Frequency of pool/spa use

• •  Number of people

Number of people

• •  Water temperature

Water temperature

• •  Phosphate levels

Phosphate levels

• •  Time of last drain and refill

Time of last drain and refill

• •  Presence of an ozone generator

Presence of an ozone generator

After this period of initial testing, your 

After this period of initial testing, your MegaChlor

MegaChlor will automatically keep your water chlorinated. To

 will automatically keep your water chlorinated. To

determine which level to test first, see the chart below for the estimated power level for your pool/spa 

determine which level to test first, see the chart below for the estimated power level for your pool/spa 

size. This is only a starting point, and the final level may be very different, per the factors listed above.

size. This is only a starting point, and the final level may be very different, per the factors listed above.
Here is how you can test which level is right for your pool or spa:

Here is how you can test which level is right for your pool or spa:

• •  Day 1: Set the power level according to the table below and the size of your pool or spa.

Day 1: Set the power level according to the table below and the size of your pool or spa.

• •  Day 2: Measure the chlorine level at the end of a chlorine generation cycle. If it is higher than you 

Day 2: Measure the chlorine level at the end of a chlorine generation cycle. If it is higher than you 

want, lower the power level by 1. If it is lower than you want, raise the power level by 1.

want, lower the power level by 1. If it is lower than you want, raise the power level by 1.

• •  Day 3: Repeat the Day 2 step until the chlorine remains constant at the desired level for a couple 

Day 3: Repeat the Day 2 step until the chlorine remains constant at the desired level for a couple 

of days.

of days.

Power Level

1-3

1-3

7-10

7-10

66

55

44

Gallons

< 1,000

< 1,000

> 10,000

> 10,000

6,000-10,000

6,000-10,000

3,000-6,000

3,000-6,000

1,000-3,000

1,000-3,000

Liters

< 3,800

< 3,800

> 38,000

> 38,000

23,000-38,000

23,000-38,000

12,000-23,000

12,000-23,000

3,800

3,800-12,000

-12,000

Note:

Note:

 If the chlorine level is 0 PPM (parts per million), even 24 hours after installation, the initial chlorine 

 If the chlorine level is 0 PPM (parts per million), even 24 hours after installation, the initial chlorine 

demand on the pool or spa may be above what 

demand on the pool or spa may be above what MegaChlor

MegaChlor can produce in order to break away from 

 can produce in order to break away from 

zero. In this case, manually add chlorine or shock (according to the product label) to assist in the initial 

zero. In this case, manually add chlorine or shock (according to the product label) to assist in the initial 

setup. You also may need to add more salt, particularly if you are using a mineral-enhanced salt like 

setup. You also may need to add more salt, particularly if you are using a mineral-enhanced salt like 

Dead Sea Salt, since only the sodium chloride (NaCl) in the water will produce chlorine. We recommend 

Dead Sea Salt, since only the sodium chloride (NaCl) in the water will produce chlorine. We recommend 

only adding a little at a time since it may take a while for it to dissolve and to change the salt indicator 

only adding a little at a time since it may take a while for it to dissolve and to change the salt indicator 

lights, and going over can cause the 

lights, and going over can cause the MegaChlor

MegaChlor to shut down to protect the power supply.

 to shut down to protect the power supply.

If pool/spa usage drops (vacation, winter, etc.), make sure to adjust the power level accordingly to 

If pool/spa usage drops (vacation, winter, etc.), make sure to adjust the power level accordingly to 

prevent over-chlorination. This is not necessary for MegaChlor-CD though, since it will automatically 

prevent over-chlorination. This is not necessary for MegaChlor-CD though, since it will automatically 

increase the time between chlorine generation cycles, using its chlorine detection.

increase the time between chlorine generation cycles, using its chlorine detection.

Summary of Contents for MegaChlor

Page 1: ...nstallation Operation Installation Operation Manual Manual ControlOMatic Inc ControlOMatic Inc 12146 Charles Drive Grass Valley CA 95945 12146 Charles Drive Grass Valley CA 95945 530 205 4520 530 205...

Page 2: ...n snow condensation etc the elements i e direct sun rain snow condensation etc WARNING WARNING 8 8 Cutting the cord from the power supply to the Cutting the cord from the power supply to the MegaChlor...

Page 3: ...rode during DO NOT handle the MegaChlor electrode during chlorine generation visible bubbling Slight discomfort may be felt chlorine generation visible bubbling Slight discomfort may be felt in cuts s...

Page 4: ...he recommended levels indicated in should be drained rinsed refilled with fresh water and balanced to the recommended levels indicated in this section We have included test strips to help you measure...

Page 5: ...Chloride NaCl Chlorine Salt Sodium Chloride NaCl For chlorine raise the salt level to 3000 PPM parts per million Pool salt is the most common salt For chlorine raise the salt level to 3000 PPM parts...

Page 6: ...mount of salt directly into the water evenly inside the perimeter of the pool or spa to bring the concentration to the recommended level Then if available turn on the jets circulation system etc to he...

Page 7: ...g style is for 110 VAC have a licensed electrician install a 220 VAC GFCI protected connection that will accept a 110 VAC style plug Please check your local electrical GFCI protected connection that w...

Page 8: ...ws and slide the box down 3 3 Tighten the screws Tighten the screws Drape the MegaChlor Electrode Drape the MegaChlor Electrode Lift the lid off the pool or spa if applicable and drape the electrode o...

Page 9: ...number of times indicating the software version For lights a number of times indicating the software version For MegaChlor CD only the MegaChlor CD only the White White and and Green Green Salt High...

Page 10: ...button as opposed to automatically turning on when the chlorine is low the above lights may flash instead of being solid Standby Mode Not Making Chlorine When in standby mode the MegaChlor will flash...

Page 11: ...indicates that longer it runs the more chlorine it adds to your water For example the factory setting of 3 indicates that the the MegaChlor MegaChlor will run for 2 hours per cycle will run for 2 hou...

Page 12: ...step until the chlorine remains constant at the desired level for a couple Day 3 Repeat the Day 2 step until the chlorine remains constant at the desired level for a couple of days of days Power Leve...

Page 13: ...n actively producing chlorine electrode has been actively producing chlorine The typical lifespan of the electrode is 7000 hours of chlorine generation To view the lifespan The typical lifespan of the...

Page 14: ...uilt in sensor to measure for the absence of chlorine When the sensor value drops below the zero point your to measure for the absence of chlorine When the sensor value drops below the zero point your...

Page 15: ...t of the bucket that is pool spa water is the level to which you should drain your pool or spa to then refill with fresh water For example if the light turns you should drain your pool or spa to then...

Page 16: ...the much salt i e when both the Green Green and and Red Red lights are on the lights are on the MegaChlor MegaChlor will pause chlorine will pause chlorine generation so as not to draw too much curren...

Page 17: ...o cause failure It is recommended that proper water balance practices be implemented especially cause failure It is recommended that proper water balance practices be implemented especially regarding...