This thermostat is designed to be connected to low voltage (24 volt and milivolt) control wires only! Do not connect
directly to wires carrying regular household voltage (120V /240V) as it would be dangerous.
For details on compatibility of your particular equipment, please call our technical assistance line.

HEATING/COOLING SYSTEMS

COMPATIBILTY

Gas – Standing Pilot

Gas – Electronic Ignition

Gas – Fire Boiler

Some Models

Gas – Millivolt System

Oil – Fire Boiler

Some Models

Oil – Fire Furnace

Electric Furnace

Electric Air Conditioner

Baseboard Electric Heater (120/240V)
Heat Pump / Single-Stage equipment
Heat Pump / Multi-Stage equipment

 

WARNING – Not for high voltage (120V or 240V) systems. Do not wire directly to household electricity.

Summary of Contents for M6004

Page 1: ...millivolt heating systems IMPORTANT This thermostat is NOT compatible with any 120V or 240V high voltage control system Read and understand this manual before installation or use Instruction Manual m...

Page 2: ...or Installaton Replacing Old Thermostat Wiring Connecting the Wires to the Terminals Mounting the Thermostat Back cover Buttons LCD Display Changing Batteries Memory backup for the Programs and Thermo...

Page 3: ...ting in half degrees Large LCD display with back light 12 or 24 hour clock display Automatic manual and extra ventilation fan modes Cycling rates to customize the efficiency for your home heating syst...

Page 4: ...lock any ventilation openings of the thermostat Do not expose this thermostat to dripping or splashing Do not expose this thermostat to excess heat Do not attempt to disassemble repair or modify this...

Page 5: ...cular equipment please call our technical assistance line HEATING COOLING SYSTEMS COMPATIBILTY Gas Standing Pilot Gas Electronic Ignition Gas Fire Boiler Some Models Gas Millivolt System Oil Fire Boil...

Page 6: ...from a lamp sun fireplace or other temperature radiating objects which may cause false readings Near or in direct airflow from supply registers and return air grills Near concealed pipes and chimneys...

Page 7: ...tem when outside temperature is below 10 C 50 F to avoid damaging the compressor Test the system to make sure that your heating and cooling are working properly before installation If either does not...

Page 8: ...THERMOSTAT The wires are usually designated W Y G RH RC B O or humidistat wires Disconnect wires from old thermostat or sub base As you disconnect each wire use masking tape to label it with the old...

Page 9: ...utput H1 H2 Humidifer control Rc Common for Cooling and Fan Rh Common for Heating W Heat output 2 Wire Heating Rc Rh Common Rc and Rh jumper is optional 3 Wire Heating Rc Rh Common Rc and Rh must be c...

Page 10: ...ommon Rc and Rh must be connected with jumper 5 Wire Heating Cooling 2 separate transformers Heat Cool Rc Rh Common wire separately jumper must not be installed Wiring Diagrams 5 Wire Heating Cooling...

Page 11: ...2 terminals marked H1 and H2 on the thermostat The original humidistat should be removed or set to OFF position The 2 humidifier control terminals H1 and H2 are electrically isolated from the Heat Coo...

Page 12: ...en the wires Make sure the wires do not touch or short circuit with other terminals Depending on your heating cooling equipment you may need to connect between 2 and 7 wires If you have 2 R wires then...

Page 13: ...level to make sure the thermostat is positioned straight Remove the back cover from the wall and drill two 3 16 4 8mm holes in the marked screw positions Insert the wall anchors into the holes complet...

Page 14: ...13 Buttons Operation...

Page 15: ...14 LCD Display Operation...

Page 16: ...the rest of the program settings press DONE when finished viewing Current Temperature The current room temperature is displayed on the left of the LCD screen Relative Humidity Relative humidity is dis...

Page 17: ...In case of power outages this thermostat has a memory backup powered by a 3V CR2025 lithium battery The lithium battery will typically last for several years Memory storage includes all set programs a...

Page 18: ...panel of the thermostat The LCD display with blank out and the show the temperature of the room in Celsius C with the display flashing Press UP or DOWN to permanently change the temperature to F Set...

Page 19: ...e and want the house at a comfortable temperature typically warmer settings during winter and cooler settings during summer PROGRAM 4 NIGHT This is a sleep mode You may choose to set temperature for e...

Page 20: ...l blink indicating that the temperature setting can be changed 7 Press UP or DOWN to adjust the temperature 8 Press NEXT to advance to settings for P2 9 Continue to press NEXT to view or adjust the re...

Page 21: ...time for P1 5 Press NEXT to adjust the temperature setting for P1 6 Temperature for P1 will blink indicating that the temperature setting can be changed 7 Press UP or DOWN to adjust the temperature 8...

Page 22: ...ons 4 Press DONE to save setting and to exit Note The humidifier will automatically turn on if the relative humidity is lower than the humidity setting Humidity is set in increments of 5 The humidity...

Page 23: ...ation press FAN until the VENT symbol appears System Mode HEAT COOL OFF In normal schedule running mode press SYSTEM button to toggle between the modes HEAT The system is in HEAT mode and furnace or h...

Page 24: ...sequences so there may be a delay of several minutes before the override settings will activate the heating cooling system HOLD FUNCTION The HOLD function will maintain a constant temperature similar...

Page 25: ...em ON time the time the heating cooling equipment is running In Schedule running mode right side of the LCD screen the USAGEsymbol will appear Press the button once to view USAGE TODAY Press the butto...

Page 26: ...N to select the VALUE Once the correct value is displayed press the OPTION button again to the next option OPTIONAL SETTINGS 1 12 24 12 or 24 hour display format 2 CR Cycle Rate setting select cycle r...

Page 27: ...0 to Cr 4 by pressing UP or DOWN See Chart 1 Press OPTION to confirm the setting and to advance to the next option Note The default setting is Cr 3 for gas or oil forced air Cr 0 is a fixed span opera...

Page 28: ...system not the thermostat This is the correct setting for most systems Note the HG display on LCD looks like H9 4 BL Backlight setting Select the setting by presing UP or DOWN BL2 ON Pressing any butt...

Page 29: ...SET To clear the permanent memory including all stored programs and settings or to change the temperature scale C or F a hard reset must be performed Press and hold the fourth button and at the same t...

Page 30: ...Programming with 4 programs per day Temperature display range 0 C 55 C 32 F 131 F Temperature setting range 5 C 35 C 41 F 95 F Humidity display range 15 to 95 Humidity setting range 20 to 70 Battery...

Page 31: ...hium battery Heat will not come on Check and ensure that the thermostat is set to HEAT mode Check and ensure that the set temperature is higher than the current room temperature You may have to wait u...

Page 32: ...ng or cooling systems on before my programmed set times This is normal if the Pre comfort Recovery system is enabled The Pre comfort Recovery will activate the heating cooling in advance of the actual...

Page 33: ...t is still cycling too often you may wish to try a slower cycle rate or disable the cycling Humidifier will not come on Check and ensure that the thermostat is set to HEAT mode Check and ensure that t...

Page 34: ...h a dated proof of purchase to the retailer from which you purchased it NOT COMPATIBLE WITH ANY 120 240 VOLT CIRCUIT CONTROL by par Canarm Customer Service number English 1 800 265 1833 Num ro du Serv...

Reviews: