UD55 User Guide
Issue code: 55nu3
14
8 Related parameters
(
Not applicable to the Commander GP Drive
)
Use parameters
11.38
and
11.39
find the operating mode for a particular
parameter-set, or to find if a parameter-set is empty.
11.38
UD55 parameter-set
selector
ô
(See below)
ð
0
RW Uni P
Range
UD55 fitted 1 ~ 8
UD55 not fitted 0
Use
11.38
to select a parameter-set in the UD55.
11.39
UD55 operating-mode
indicator
ô
OPEN.LP
CL.VECt
SErVO
rEGEn
FrEE
ð
0
1
2
3
4
RO Uni P
11.39
indicates the operating mode related to the parameter-set selected
in
11.38
. When the selected parameter-set contains no values,
11.39
indicates
FrEE
.
11.40
UD55 full parameter checksum
ô
0 ~ 16383
ð
RO Uni P
When parameter values are copied to the UD55, a checksum is calculated
from all the parameter values.
11.40
contains the value of the checksum of
the parameter values contained in the parameter-set selected in
11.38
.