background image

2

1. 

POWER REQUIREMENTS

:

Must use Class 2 or SELV rated power supply.
Power connection via removable three position terminal block.

Supply Voltage:

+24 VDC ±20%

Typical Power

1

:

27 W

Maximum Power

2

:

67 W

Notes: 

1. Typical power with +24 VDC, RS232/485 communications, Ethernet

communications, CompactFlash card installed, and display at full brightness.

2. Maximum power indicates the most power that can be drawn from the

315. Refer to “Power Supply Requirements” under “Installing and
Powering the 315.”

3. The 315’s circuit common is not connected to the enclosure of the unit.

See “Connecting to Earth Ground” in the section “Installing and
Powering the 315.”

4. Read “Power Supply Requirements” in the section “Installing and

Powering the 315” for additional power supply information.

2. 

BATTERY

: Lithium coin cell. Typical lifetime of 10 years.

3. 

LCD DISPLAY

:

*Lifetime at room temperature. Refer to “Display” in “Software/Unit Operation”
4. 

10-KEY KEYPAD

: for on-screen menus.

5. 

TOUCHSCREEN

: Resistive analog

6. 

MEMORY

:

On Board User Memory

: 32 Mbyte of non-volatile Flash memory.

Memory Card

: CompactFlash Type II slot for Type I and Type II

CompactFlash cards.

7. 

COMMUNICATIONS

:

USB Device Port

: Adheres to USB 2.0 Specification supporting high speed

and full speed via Type B connection.

Serial Ports

: Format and Baud Rates for each port are individually software

programmable up to 115,200 baud.
PGM Port: RS232 port via RJ12.
COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12.
DH485 TXEN: Transmit enable; open collector, V

OH

= 15 VDC, 

V

OL

= 0.5 V @ 25 mA max.

Note: For additional information on the communications or signal

common and connections to earth ground please see the “Connecting to
Earth Ground” in the section “Installing and Powering the 315.”

Port to port isolation: 500 Vrms for 1 minutes signal isolation : 50V

Ethernet Port

: 10 BASE-T / 100 BASE-TX

RJ45 jack is wired as a NIC (Network Interface Card).
Isolation from Ethernet network to CTVue operator interface: 1500 Vrms

8. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature Range

: 0 to 50°C

Storage Temperature Range

: -20 to 70°C

Operating and Storage Humidity

: 80% maximum relative humidity (non-

condensing) from 0 to 50°C.

Altitude

: Up to 2000 meters.

9. 

CERTIFICATIONS AND COMPLIANCES

:

SAFETY

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment

for measurement, control, and laboratory use, Part 1.

IP66 Enclosure rating (Face only), IEC 529
Type 4X Enclosure rating (Face only), UL50

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for

Measurement, Control and Laboratory use.

Note:

1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self
recovers.

10. 

CONNECTIONS

: Compression cage-clamp terminal block.

Wire Gage: 12-22 AWG copper wire
Torque: 5-7 inch-pounds (56-79 N-cm)

11.

CONSTRUCTION

: Steel rear metal enclosure with NEMA 4X/IP66

aluminum front plate for indoor use only when correctly fitted with the gasket
provided. Installation Category II, Pollution Degree 2.

12. 

MOUNTING REQUIREMENTS

: Maximum panel thickness is 0.25" (6.3

mm). For NEMA 4X/IP66 sealing, a steel panel with a minimum thickness of
0.125" (3.17 mm) is recommended.

Maximum Mounting Stud Torque

: 17 inch-pounds (1.92 N-m)

13. 

WEIGHT

: 11.41 lbs (5.17 Kg)

DIMENSIONS  In inches (mm)

S

PECIFICATIONS

SIZE

15-inch

TYPE

TFT

COLORS

32K

PIXELS

1024 X 768

BRIGHTNESS

600 cd/m

2

BACKLIGHT

*

50,000 HR TYP.

Class A

EN 55011

Emissions

Emissions:

3 V/rms

Criterion B

EN 61000-4-6

RF conducted interference

2 kV L&N-E power

2 kV power

Criterion B

EN 61000-4-4

Fast transients (burst)

Criterion A

EN 61000-4-5

Surge

1 kV L-L,

10 V/m

Criterion B

EN 61000-4-3

Electromagnetic RF fields

1 kV signal

8 kV air discharge

4 kV contact discharge

Criterion A

EN 61000-4-2

Electrostatic discharge

Immunity to Industrial Locations:

WARNING - DO NOT CONNECT OR DISCONNECT CABLES
WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE
NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND
DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT
CONNECTION.

Summary of Contents for DRIVE CENTRE 315C

Page 1: ...her actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller CompactFlash is a registered trademark of CompactFlash...

Page 2: ...ernet network to CTVue operator interface 1500 Vrms 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 20 to 70 C Operating and Storage Humidity 80 maximum rela...

Page 3: ...ts of power Items that could cause increases in current are additional communications optional communications card CompactFlash card and other features programmed through CTVue Configurator In any cas...

Page 4: ...er This driver is installed with CTVue Configurator and is located in the folder C Program Files Control Techniques CTVUE Device after CTVue Configurator is installed This may have already been accomp...

Page 5: ...an be used for either master or slave protocols DH485 Connections The 315 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to co...

Page 6: ...fault status of the LEDs 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the...

Page 7: ...TIONAL FEATURES AND ACCESSORIES COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards Use cards with a minimum of 4Mbytes with the 315 s CompactFlash so...

Page 8: ......