Operating Instructions
UPON ALARM
The Freeze Alarm will call out with one or more of the following messages:
"There is a temperature alarm emergency at location (your four digit security/location code). Help
is needed immediately!"
AND/OR
"There is a power alarm emergency at location (your four digit security/location code). Help is
needed immediately!"
AND/OR
"There is a battery alarm emergency at location (your four digit security/location code). Help is
needed immediately!"
The alarm message(s) is repeated once, followed by:
"To disable the alarm call out, enter your four digit security code followed by the star key."
You must enter the correct security code within 15 seconds or the Freeze Alarm will hang up
and call again in the selected interval (15 minutes or 2 hours). If you enter the correct security
code within 15 seconds you will hear:
"The alarm call out is now disabled. To return to main menu, press 1, otherwise hang up."
You now have the option of returning to the main menu to review or change the system data.
IMPORTANT:
The Freeze Alarm will continue to call out with an alarm message until disabled, even if alarm
conditions have been corrected.
CALLING THE VOICE DIALER FROM A REMOTE LOCATION
When called from a remote location, the Freeze Alarm will answer after five rings and you will hear:
"Enter the security code followed by the star key."
If you enter the correct security code within 15 seconds, and the Freeze Alarm is not in alarm,
you will enter the main menu and hear:
"You are now in the main menu. To review or program. . ."
If the Freeze Alarm is in alarm, you will hear one of the three alarm messages described in
Operating Instructions above. The alarm message is repeated once, followed by:
"To disable the alarm call out, press 0. Otherwise, to return to the main menu, press 1."
For information on compatiblity with answering machines, see "IMPORTANT INFORMATION" section.
Alarm delay feature:
If dip switch #6 is placed in the DOWN position, the Freeze Alarm will delay 45
minutes during a temperture alarm only. A temperature alarm condition must be
present for 45 minutes before unit will call out.
IMPORTANT INFORMATION
Power alarm delay feature:
The power alarm delay is selectable from either 1 hour or 0 minutes.
Battery alarm feature:
The battery voltage is checked every 10 minutes. A low battery alarm will occur if the
voltage drops below 7 volts.
Using Freeze Alarm on the
The Freeze Alarm does not require a dedicated phone line and can share the same
same phone line as telephone:
jack with a telephone by using a dual plug adapter (not included). Caution: The Freeze
Alarm may not work on a PBX or multi-line systems or a party line.