TECHNICAL SPECIFICATIONS
INPUT VOLTAGE:
230V - 240V AC 50Hz
CONTROLLER VOLTAGE:
24V DC
STANDBY POWER:
2.8 Watts
MOTOR POWER:
100 Watts
MOTOR TYPE:
24V DC Permanent Magnet
OPERATING TEMPERATURE:
+5° to +40°C
MAXIMUM DOOR OPENING:
1,2
WIDTH:
5500mm
HEIGHT:
2700mm
WEIGHT:
100Kg
RATED LOAD:
450N (45Kg)
RECOMMENDED LOAD:
200N (20Kg)
OPENER LIMITS TRAVEL:
3.0 Turns of Door Drum Wheel
OPERATING TIME - INTERMITTENT:
4 Minutes
RECEIVER TYPE:
UHF 433.92 MHz. AM Receiver
RECEIVER CODE STORAGE CAPACITY:
6 Smart Code Transmitters
1 Dipswitch Transmitter
1 Entry Keypad
TRANSMITTER FREQUENCY:
433.92 MHz
CODING TYPE:
Fixed
No. of CODE COMBINATIONS:
Over 3.86 Billion Codes
TRANSMITTER BATTERY:
2 x 3V Type 2032 Button Cell
DEFAULT SETTINGS AND SPECIFICATIONS
16
Note:
1. The maximum continuous curtain residential roll up door opening that the Shed Master can be installed on is 5500mm wide by
2700mm high. The door must be well balanced. A person of average strength should be able to lift up the door manually with very
little effort in case of an emergency.
2. Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure on the door
and tracks which may in turn trigger the safety obstruction detection system intermittently.
DEFAULT
STEP
MAXIMUM
MAXIMUM MOTOR RUN TIME
30 Secs.
—
—
OBSTRUCTION FORCE MARGIN
8
1
20
FACTORY DEFAULT SETTINGS
©Copyright 2006 B&D Doors