background image

PE BEAM AND FINAL SET UP

14

13. FITTING THE SAFETY PHOTO 

ELECTRIC BEAM SENSOR (OPTIONAL)

Locate the Photo Electric Beam (P.E.) normally closed contact

type  in  a  strategic  location  within  doorway.  We  recommend

150mm  above  the  floor  level  and  as  close  as  possible  to  the

door  opening,  inside  the  garage.  Remove  shunt  from  P.E

connector (

Fig. 14

) and connect the wires from the P.E. wiring

harness as per 

Fig. 15

.

Note:

The  wiring  diagram  is  for  a Transmitter/Receiver  type

photo  electric  beam:  model:  PE-2  (Order  Code  90214)  with

Wiring Harness (Order Code 01900).

Make  sure  to  align  the  beams  correctly.  Follow  the  manual 

supplied with the Photo Electric Beam.

WARNING; The location of the beam and manner in which

it is installed might not give safety protection at all times.

Check to make sure that the height of the beam and type

used give maximum protection possible. 

14. MANUAL RELEASE

To  switch  the  opener  to  manual  mode  simply  pull  the  red 

manual  release  handle  down  and  release.  To  re-engage  the

opener repeat the above action (

Fig. 16

).

Note:

The door may move uncontrollably if the spring tension

is weak or not set properly or the door is unbalanced. If this

occurs  do  not  use  the  door  and  contact  your  installer  for 

service.

The manual release handle can be locked to prevent unwanted

disengagement  (where  fitted).  This  is  useful  if  the  opener  is

mounted on an exposed carport or perimeter door. To disable

the manual release turn the key clockwise to the locked position

as indicated on the label. To enable turn the key anti-clockwise.

15.  RESET ALL FACTORY DEFAULTS

1.  Turn power off.

2.  Press and hold Set button.

3. Turn power on and continue holding Set until all LEDs are 

off.

Note:

This does not erase transmitter codes stored in memory.

16.  RE-INITIALISING THE OPENER

To re-initialise the opener press and hold the Set Button for two

(2) seconds, the beeper will sound once. The door will start to

move  and  re-calculate  force  margins.  The  door  can  move

between the open and close limit positions  up to four (4) times

(depending  on  the  position  of  the  door  and  the  power  up 

condition). A single beep will be heard once the initialisation is

complete. The door is now ready for use.

FIG. 14

FIG. 15

Model: PE-2

FIG. 16

REMOVE

PE SHUNT

1 2  3  4  5

0V

PE

24V

©Copyright 2006 B&D Doors

Summary of Contents for Controll-A-Door ShedMaster

Page 1: ...s to follow all instructions Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please...

Page 2: ...4 15 16 17 18 19 20 B D Doors to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions...

Page 3: ...s vital for the safety of persons to follow all instructions Failure to comply with the following Safety Rules may result in serious personal injury and or property damage The unit is rated to IP24 ho...

Page 4: ...should be checked at least once a month See installation manual for instructions LOCKABLE CONTROL PANEL The control panel can be locked and disabled to prevent tampering This is useful if the opener i...

Page 5: ...factors wind etc affect the operations of the door opener PLUS button green can be used during installation to set the open limit position Pressing this button will move the door in the open direction...

Page 6: ...DE BUTTON BLACK 5 CODING LED RED 6 SET BUTTON ORANGE 7 OPERATE BUTTON BLUE 8 FORCE MARGIN SET BUTTON 9 PLUS BUTTON FOR LIMITS SETTING FORCE MARGIN 10 OPEN LIMIT LED GREEN 11 MINUS BUTTON FOR LIMITS SE...

Page 7: ...N FLAT WASHER I D 3 16 x 1 2 2 2 S R E V O C R A B G N I K C O L 1 L A U N A M N O I T A L L A T S N I Copyright 2006 B D Doors TRANSMITTER B D CONTROLL A DOOR SHEDMASTER DRIVE UNIT COLLAR KIT 1 SELF...

Page 8: ...ck or bind in the guide tracks The ideal operational effort in raising or lowering the door should not exceed a force of 10kg 22 lbs Make sure that all door locks ropes chains etc are either released...

Page 9: ...hand door mounting bracket from wall 6 Remove the drive assembly from the packaging Try to rotate the drive gear by pushing on the fork If the gear does not rotate the manual mode has to be selected T...

Page 10: ...cure the curtain to drum wheel using self drilling screws two on each end The screws should be at least 90 degrees apart FIG 7 Copyright 2006 B D Doors DRUM WHEEL 5 1 MOUNTING THE TRANSMITTER BRACKET...

Page 11: ...OOR LIMITS POSITIONS The door limit positions can be deleted for new positions by following the steps below 1 Press and hold the Minus button Fig 10 for six 6 seconds until you hear three beeps and th...

Page 12: ...1 Press and hold the Force Margin Set button Fig 11 2 While holding down the Force Margin button press the Plus button Each press increases the force margin in both directions The Open Limit LED will...

Page 13: ...ter the code is now set 10 1 SETTING ENTRY KEYPAD TRANSMITTER CODE 1 Make sure that the battery is set in the Keypad Transmitter 2 Press the Code Set button on the opener the Code Set LED will illumin...

Page 14: ...e The door may move uncontrollably if the spring tension is weak or not set properly or the door is unbalanced If this occurs do not use the door and contact your installer for service The manual rele...

Page 15: ...de Codes a transmitter button for OPERATE function Force Margin Set Plus Increases the obstruction force margin setting Force Margin Set Minus Decreases the obstruction force margin setting Force Marg...

Page 16: ...No of CODE COMBINATIONS Over 3 86 Billion Codes TRANSMITTER BATTERY 2 x 3V Type 2032 Button Cell DEFAULT SETTINGS AND SPECIFICATIONS 16 Note 1 The maximum continuous curtain residential roll up door...

Page 17: ...tracks Possible obstruction in the doorway Increase force margin setting See Step 8 3 on page 13 Or re calculate force margin See Step 8 6 on page 13 Remove obstruction Door operates from drive unit O...

Page 18: ...ORMER TDB 72 01 KIT 72VA 62079 RATCHET TIMING ASSY 62078 POWER CORD A S 1 5M 2P1R 62081 FELT 21 X 29 TERMINAL BLOCK 500 02DS 2 POS CAP POLYFILM 0 1UF K X2 275 VAC HEX SERRATION HEAD SCREW M8X16 TAPTIT...

Page 19: ...for any service call made by B D or an Authorised Distributor where such a call is made for the purpose of adjustment as described in the Manufacturers Written Instruction Manual and not for rectifica...

Page 20: ...difications or repairs made or attempted to be made by any unauthorised person vii Faulty electrical wiring of structures to which the Opener is affixed viii Radio or other electronic interference inc...

Reviews: