Door  lock  connection

–Either  connect  the  electric  lock  to  the  Active  output,  which  also 

provides  power,  or  switch  the  external  power  supply  using  a  relay.  In  either  case,  we 
recommend  that  you  to  use  low-power  locks  and  keep  the  above-mentioned  maximum 
values. 

Where  coil-containing  devices  such  as  relays  or  electromagnetic  locks  are  used,  make  sure 

that the intercom output is protected against surge when the induction load is switched off. 

For this method of protection, we recommend a 1A/1,000V (e.g., 1N4007, 1N5407, 1N5408) 

diode connected antiparallel and placed as close as possible to the lock. 

 
Restoring  factory  defaults

–Follow  the  instructions  below  to reset  the  factory  default 

values: 

 

Press the RESET button. 

 

Wait  until  the  red  and  green  LEDs  on  the  device  come  on  simultaneously         

(about 20 s). 

 

Wait until the red LED turns off (about 5 s). 

 

Wait until the green LED turns off and the red LED turns on again (about 5 s). 

 

Wait until the red LED turns off (another 5 s). 

 

Release the RESET button. 

 

IP address: 

 

Default setting is DHCP ON.

 

 

To switch DHCP ON/OFF, press the dial button 15x within 30 seconds from bootup.

 

 

Press the dial button 4x within three seconds to identify the door station to Control4.

 

 
 
Maintenance

–Cleaning 

The device surface can get dirty  when used frequently. Use a piece of soft cloth moistened 

with clean water to clean the device. 

 

 

  

Summary of Contents for DS2 MINI

Page 1: ...DS2 MINI ...

Page 2: ...e device to the base Caution When the proper mounting instructions are not met water might get in and destroy the electronics The intercom circuits are constantly powered and water infiltration causes an electro chemical reaction The manufacturer s warranty will be void for products damaged in this way Electric installation Description of connector terminals Description of motherboard connectors a...

Page 3: ...ose as possible to the lock Restoring factory defaults Follow the instructions below to reset the factory default values Press the RESET button Wait until the red and green LEDs on the device come on simultaneously about 20 s Wait until the red LED turns off about 5 s Wait until the green LED turns off and the red LED turns on again about 5 s Wait until the red LED turns off another 5 s Release th...

Page 4: ...e product defects and failures arisen as a result of improper mounting in contradiction with these instructions The manufacturer is not liable for damage caused by theft within an area that is accessible after the attached electric lock is switched on The product is not designed as a burglar protection device except when used in combination with a standard lock which has the security function This...

Page 5: ...L16 16 kHz Camera Resolution JPEG 1280 x 960 px Resolution video call 640 x 480 px Viewing angle 120 H 90 V 145 D Night vision Yes Video stream Codecs H 263 H 263 H 264 MJPEG MPEG 4 Interfaces Power supply 12V 15 2A DC or PoE PoE PoE 802 3af Class 0 12 95 W LAN 10 100BASE TX with Auto MDIX RJ 45 Switch output NC NO contacts max 30V 1A AC DC Active switch output 8 to 12VDC depending on power supply...

Page 6: ...158 F 40 C to 70 C Operating relative humidity 10 to 95 non condensing Officially certified outdoor coverage level IP54 IK08 Dimensions Frame for surface installation 1 module 107 x 130 x 28 mm 4 21 x 5 12 x 1 10 inches Frame for flush installation 1 module 130 x 153 x 5 mm 5 12 x 6 02 x 0 20 inches ...

Page 7: ......

Page 8: ...Control4 Corporation 11734 South Election Road Salt Lake City UT 84020 USA 2294v1 ...

Reviews: