background image

32

Figure 12.  Heat Pump, Single Stage Wiring

Summary of Contents for CCZ-T1-W

Page 1: ...Wireless Thermostat Installation Guide...

Page 2: ...he Control4 certified logo are registered trademarks or trademarks of Control4 Corporation in the United States and or other countries All other names and brands may be claimed as the property of thei...

Page 3: ...ecifications 3 Pre Installation Considerations 4 Installation Instructions 7 Composer Programming Instructions 11 Thermostat Relays 16 Troubleshooting 22 Installing a Bypass Resistor to Enable Power S...

Page 4: ......

Page 5: ...rred with the misuse of this product See the warranty information in the Control4 Wireless Ther mostat User Guide or on the Control4 website at www control4 com warranty Important Safety Instructions...

Page 6: ...s 4 6 x 7 8 Warranty card U shaped terminal jumper wire Requirements Pencil 2 or darker Drill with 3 16 drill bit Small level optional Small flat blade screwdriver Phillips screwdriver Tape for labeli...

Page 7: ...battery Power Usage 1 10W at 24VAC 50 60 Hz Set Point Temperature Range 40 F to 90 F 5 C to 32 C Operating Temperature 39 F to 131 F 4 C to 55 C Storage Temperature 14 F to 185 F 10 C to 85 C Operatin...

Page 8: ...e in a power stealing condition when there is no availability of a dedicated common wire However Control4 recommends using a dedicated common wire whenever possible With some HVAC systems power steali...

Page 9: ...in the wall where the Thermostat is located Run a wire to the furnace and install the Thermostat next to the furnace See Remote Temperature Sensor Use a separate 24VAC transformer to power the Thermo...

Page 10: ...ocated near the HVAC equipment with only the Remote Temperature Sensor on the wall in the living area This creates a much cleaner install In this case the Thermostat settings would be con trolled usin...

Page 11: ...wer supply for the HVAC system If installing a Thermostat in a new location refer to Sample Wiring Configurations later in this document for details on wiring the Thermostat and then go to Step 5 If r...

Page 12: ...e rear plate of the new Wireless Thermostat to place the rear plate against the wall see Figure 3 5 6 7 8 9 10 11 12 13 Insert the mounting screws included into the plastic wall anchors and firmly tig...

Page 13: ...eat pump system s b Set the Primary middle switch to select Primary stage fan control Fuel The gas or oil furnace equipment controls the fan in heating default Electric The Thermostat controls the fan...

Page 14: ...uto and Manual modes to confirm that both the furnace and air conditioner cycle on and off at the appropriate settings To operate the Thermostat see the Control4 Wireless Thermostat User Guide on the...

Page 15: ...roducts resources which includes basic Thermostat pro gramming instructions using a Touch Screen On Screen Navigator or MyHome app Ensure that the Wireless Thermostat is installed as directed in this...

Page 16: ...Thermostat NOTE If buttons are disabled they will be re enabled when the Thermostat power cycles This is a safety mechanism to prevent a Thermostat from becoming completely inoperable if it were remov...

Page 17: ...ple If the Thermostat reads 72 degrees Fahrenheit and the current temperature is determined to be 70 degrees Fahrenheit press the down button two 2 times to lower the Thermostat reading to 70 degrees...

Page 18: ...ure does not reach the designated Cutoff Point before the Maximum Run Time is reached the cooling system will shut off and not initiate cooling again until the Minimum Off Time is reached NOTE Some HV...

Page 19: ...e temperature reaches the designated Cutoff Point before the Minimum Run Time is reached the system will not shut off until the Minimum Run Time is reached Also if heat or cool is engaged and shut off...

Page 20: ...g Primary Fan Fuel Secondary Fan Fuel Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage Primary Fan Electric Secondary Fan Fuel Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage Primary Fan Fuel Secondary Fan Ele...

Page 21: ...elay allowing the furnace to control the fan The switch in the electric position causes the Thermostat to activate the G fan relay allowing the Thermostat to control the fan Conventional Stage Cooling...

Page 22: ...Primary Fan Fuel Secondary Fan Electric Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage Heat Pump Heating Primary Fan Fuel Secondary Fan Fuel Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage 3rd Stage Before A...

Page 23: ...tage 2nd Stage 3rd Stage Before Aux Stage Delay Auxiliary Stage After Aux Stage Delay E Heat Stage 1 Primary Fan Fuel Secondary Fan Electric Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage 3rd Stage Befor...

Page 24: ...t pump is connected to a furnace system with the heat pump heat exchanger in line downstream from the furnace hot air In this case Y1 and Y2 will de energize after a configurable auxiliary heat cutoff...

Page 25: ...1st Stage 2nd Stage Primary Fan Electric Secondary Fan Fuel Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage Primary Fan Fuel Secondary Fan Electric Stage Y1 Y2 W1 W2 O B G 1st Stage 2nd Stage Primary Fan...

Page 26: ...button 9 times The Thermostat must be rebooted after changing switches so that it recognizes the changes For help on the installation or operation of the Wireless Thermostat email support control4 com...

Page 27: ...mostat Installing the bypass resistor included can help minimize the effects of power stealing on the HVAC system Some HVAC configurations however do not require the bypass resistor to reliability use...

Page 28: ...power to the HVAC system before accessing the transformer Install the resistor on the HVAC system not on the Thermostat Wire the resistor from the Heat Relay Terminal W or W1 to the common side of th...

Page 29: ...25 Figure 7 Gas Electric Single Stage...

Page 30: ...pleted wiring examples are shown below 4 5 Example 1 The first example Figure 8 shows an HVAC system with a dedicated 24V Common screw terminal on the control board The resistor simply spans be tween...

Page 31: ...mer to the control board When the bypass resistor is in place you should re assemble any covers or housings that were removed to access the transformer and control panel often safety switches prohibit...

Page 32: ...n a Wireless Thermostat IMPORTANT Do not install any Remote Temperature Sensors to the TS terminals other than supported external temperature sensors Flush Mount Remote Tempera ture Sensor Aprilaire M...

Page 33: ...t relay W2 Conventional 2nd stage heat relay Heat Pump emergency heat line O Heat Pump cool changeover valve TS Remote sensor optional accessory TS C Remote sensor optional accessory NOTES 1 Install t...

Page 34: ...30 Figure 10 Conventional Single Stage Wiring...

Page 35: ...31 Figure 11 Conventional Dual Stage Wiring...

Page 36: ...32 Figure 12 Heat Pump Single Stage Wiring...

Page 37: ...33 Figure 13 Heat Pump with Electric Auxilliary Heat Dual Stage Wiring...

Page 38: ...34 Figure 14 Millivolt Heat Conventional Cool Single Stage Wiring...

Page 39: ...35 Figure 15 Heat Pump with Electric Auxilliary Dual Stage Dual Transformer Wiring...

Page 40: ...iew regulatory information for your particular Control4 products see the information located on the Control4 website at http www control4 com regulatory Warranty Limited 2 year warranty Refer to http...