Meter mode

 

The meter mode can be selected from the counter visualization mode, holding keys 

‘A’

 and 

‘B’

 for at least 5 second. 

Measure are displayed on the right side of display, in 3-digit format 
On the left side are displayed the name of  parameter measured. 
To change the parameter, press the keys 

‘A’

 or 

‘B

’. 

Leds status are don’t care; only the pulse led show the status of last selected energy. 
To revert to the visualization in counter mode you can hold keys 

‘A’

 and 

‘B’

 for at least 5 second or enter in SETUP and 

wait the automatically exit to counter visualization measure. 
 
The following table is the list of parameter displayed in meter mode. 
 

Measure visualization in meter mode 

Parameter

 

Display

 

VOLTAGE VL1-NEUTRAL. 

Vl1  000 

VOLTAGE VL2-NEUTRAL. 

Vl2  000 

VOLTAGE VL3-NEUTRAL. 

Vl3  000 

CURRENT PHASE L1 

il1  000 

CURRENT PHASE L2 

Il2  000 

CURRENT PHASE L3 

Il3  000 

POWER FACTOR PHASE L1. 

PF1  000 

POWER FACTOR PHASE L2. 

PF2  000 

POWER FACTOR PHASE L3. 

PF3  000 

ACTIVE POWER PHASE L1. 

PL1  000 

ACTIVE POWER PHASE L2. 

PL2  000 

ACTIVE POWER PHASE L3. 

PL3  000 

REACTIVE POWER PHASE L1. 

QL1  000 

REACTIVE POWER PHASE L2. 

QL2  000 

REACTIVE POWER PHASE L3. 

QL3  000 

APPARENT POWER PHASE L1. 

SL1  000 

APPARENT POWER PHASE L2. 

SL2  000 

APPARENT POWER PHASE L3. 

SL3  000 

VOLTAGE VL1 VL2. 

V12  000 

VOLTAGE VL2 VL3. 

V23  000 

VOLTAGE VL3 VL1. 

V31  000 

FREQUENCY L1 

FRE  000 

 

NOTE regarding to the measures. 

In some applications, in which the CT's secondary is connected to other instruments, different of the EMC-D3b counters, there might be 
some measuring problems, depending on the typology of the current inputs. Optionally, there are alternatives adapted to solve these 
possible problems. 
Please get in touch with the Technical Assistance Dpt., in case of problems. 

 

NOTE regarding digital inputs. 

It is advisable to place a fast fuse 50mA 250V at the digital input. 
The maximum absorbed current is 1 mA. 
In absence of voltage at the input, the T1 time band will be selected. 
With voltage applied to the input, the T2 time band will be selected. 
 
Please refer to the technical characteristics for further information's regarding the digital inputs. 

Summary of Contents for EMC-D3b

Page 1: ...other than the standard specify when ordering power supply separated from measuring voltage specify when ordering single phase network power supply is taken from VL1 and neutral specify when ordering...

Page 2: ...nd authorised staff must carry out maintenance and or repair Should it be considered that there is a safety loss during operation the instrument must be disconnected and precautions taken against acci...

Page 3: ...ust not overcome 500 Vrms depending always on the instrument s power supply In case of three phase application with or without neutral not distributed it is enough not to connect the terminal N The tr...

Page 4: ...INSERTION ON THREE PHASE LINE WITH 4 WIRES AND 3 VT BALANCED THREE PHASE LINE LOAD P1 P1 P1 P2 S1 S1 S1 S2 N L1 L2 L3 S2 S2 S2 S1 S1 S1 I1 I2 I3 VL1 VL2 VL3 N measure cu rren t inputs measure vo ltag...

Page 5: ...erred at the L1 phase The others data displayed relatives at value of three phase system are not to consider VL1 VL2 VL3 N EMC measure vol tage in puts LOAD S2 S2 S2 S1 S1 S1 I1 I2 I3 measure cu rren...

Page 6: ...he energy counting is being accumulated on time band 2 F LED indicating energy counting The frequency of blinking is proportional to the energy displayed G LED for indication of reactive energy counti...

Page 7: ...L1 PUL 10 0 kW kVAr pulse Set pulse weight 01 0 kW kVAr pulse 00 1 kW kVAr pulse 0 01 kW kVAr pulse TPL 100 mS Set the duration pulse 200 mS 300 mS 400 mS 500 mS only for EMC D3b 485 ID Increase Set...

Page 8: ...RMAL Only one counter is available for each energy resetting the energies is available only by the front panel E TOT PAR Two counters are available for each energy the total counters are not resettabl...

Page 9: ...he instrument when it will be connected in a EIA485 communication network proceed with the modality already described The settable values are from 1 to 247 To confirm press the C key Programming of th...

Page 10: ...CHED OFF SWITCHED OFF SWITCHED OFF SWITCHED ON Energy operating mode TIME BAND Parameter LED s STATUS LED kWh LED kVARh LED T1 LED T2 Visualisation active energy T1time band Energy counting on T1 time...

Page 11: ...POWER FACTOR PHASE L3 PF3 000 ACTIVE POWER PHASE L1 PL1 000 ACTIVE POWER PHASE L2 PL2 000 ACTIVE POWER PHASE L3 PL3 000 REACTIVE POWER PHASE L1 QL1 000 REACTIVE POWER PHASE L2 QL2 000 REACTIVE POWER...

Page 12: ...80 Vac to 250 Vac 50 60Hz From 90 Vdc to 300Vcc polarised Serial output Only for EMC D3b 485 one RS485 port 2400 to 19200 baud s MODBUS RTU protocol GENERAL Display operation keys 1 display with red...

Reviews: